background image

Page 10

CHG/CHR

 

ADJUSTING FOR PROPER FLAME

Air Shutter (Figure 13)
Each burner is tested and adjusted at the factory prior to shipment.
However, variations in the local gas supply may make it necessary
to adjust the burner. The flames of the burner should be visually
checked. The burner flames should be yellow. If the burner does
not operate correctly, check if the air shutter or burner ports are
blocked by dirt, debris, spider webs, etc. and proceed with air
shutter adjustment. The amount of air which is drawn into a
burner is governed by a metal cup at the inlet of the burner called
an air shutter.

ROTATE TO ADJUST

AIR SHUTTER

AIR SHUTTER

Figure  13

Air Shutter Adjustment
Be careful as the burner may be very HOT! The air
shutter is located behind the valve cover. There is an
access area at the bottom of the valve cover where you can
adjust the air shutter, with your fingers. A sooty, yellow
flame  
indicates insufficient air. Open the air shutter to
allow more air to the burner. If flame is noisy, blows out,
or lifts away from burner or will not light
, this indicates too
much air. Close the air shutter to decrease the amount of
air to the burner.

BURNER MAINTENANCE AND CLEANING
Inspect the burner before each use of the outdoor gas fireplace.
The burner must be replaced prior to the outdoor gas fireplace
being put into operation if it is evident that the burner is damaged.
A replacement burner for this outdoor gas fireplace can be
obtained by contacting Empire Comfort Systems, Inc.

Flashback from Spiders (Figure 14)
In some areas of the country, spiders or small insects have been
found to create "flashback" problems. The spiders spin webs and/
or insects build nests in the burner venturi tube. The web and/or
nests can lead to gas flow obstruction which results in a "flashback"
(a fire in the venturi tube). Clean interior of  burner with a flexible,
soft bristle, bottle brush in order to remove spiders, spider webs
and debris. Apply air pressure to burner ports to remove debris.

Figure 14

Burner Orifice Cleaning
Apply air pressure into the burner orifice and orifice tubing to
remove spiders, spider webs, dust, lint and debris. A flexible, soft
bristle, bottle brush can be used to clean the orifice tubing.

MAIN BURNER FLAME PATTERN 

(Figure 15)

Refer to the following photograph for proper main burner flame
characteristics.

Figure  15

MAINTENANCE AND SERVICE

Содержание CHG

Страница 1: ...his equipment AVERTISSEMENT Si les informations dans ce manuel ne sont pas exactement suivies un feu ou une explosion peut en résulter causant des dommages à la propriété des blessures corporelles ou la mort Ne pas entreposer ou employer de la gazoline ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou tout autre appareil Que faire si vous sentez le gaz N essayer pas d all...

Страница 2: ...ateur pour patio seront exposés à la chaleur radiante et peuvent être endommagés MISE EN GARDE Vous devez utilisez le régulateur de gaz PL de pression à gaz fourni avec ce radiateur pour patio Ce régulateur de gaz PL est réglé pour une pression de sortie de 11 pouces de colonne d eau L alimentation du gaz doit être fermée à la bouteille de gaz PL lorsque ce radiateur pour patio n est pas utilisé L...

Страница 3: ...n of Dangerous Goods Thecylindersupplysystemmustbearrangedforvaporwithdrawal The cylinder used must include a collar to protect the cylinder valve This outdoor gas fireplace shall be used only outdoors in a well ventilated space and shall not be used in a building garage or any other enclosed area If the outdoor gas fireplace is not in use the gas must be turned off at the supply cylinder Storage ...

Страница 4: ...nders after filling Your new outdoor gas fireplace regulator is equipped with a coupling nut Do not attempt to connect any propane cylinder not equipped with a mating Type 1 cylinder valve Connecting the Regulator to the Valve Figure 1 This Type 1 cylinder valve contains a backcheck which is designed to prevent propane from flowing until the valve is properly connecting to a regulator When connect...

Страница 5: ...llation 7 Top 47 from top of unit or 96 from floor Floor Combustible Warning Whenselectingalocationforyouroutdoorchimenea it is important to consider that any ceiling overhang or other surface located above the chimenea can discolor due to heat or carbon particles generated while unit is operating Attention Raincapmustbeplacedonoutdoorchimeneawhen not in use Rain cap will prevent rain from enterin...

Страница 6: ... and 7 8 Holding the burner assembly securely with two hands tip the burner to a position where it will fit through the front door opening The gas inlet plumbing control panel and regulator hose assembly should be pointing to the left and somewhat downasyoumaneuvertheburnerthroughthedoor Guidethe regulator hose and control panel through the large hole in the bottom of the outdoor gas fireplace The...

Страница 7: ... Recesses tabs and holes are provided to locate the logs properly See Figure 10 for proper placement Installation of logs is completed Figure 10 Refer to the following warning Warning Failure to position the parts in accordance with this photograph or failure to use only parts specifically approved with this appliance may result in property damage or personal injury Figure 11 14 Attach the 20 lb L...

Страница 8: ...ch conversion label onto top portion of rating plate 17 Attach 3 8 flared fitting from Natural gas supply line or hose kit onto gas valve 18 Turn on Natural gas supply to outdoor gas fireplace and check all gas connections for leaks with soap solution watching for bubbles on all gas connections 19 The Natural gas inlet supply pressure to the gas valve on outdoor gas fireplace will be from a minimu...

Страница 9: ... an equal amount of liquid detergent and water 6 Apply soap mixture to all gas connections Soap bubbles will appear if there is a leak Tighten connections to make a proper seal If you cannot stop a gas leak turn off the gas supply and call your local gas utility or the dealer from whom the outdoor gas fireplace was purchased Onlythosepartsrecommendedbythemanufacturershould be used on the outdoor g...

Страница 10: ... Close the air shutter to decrease the amount of air to the burner BURNER MAINTENANCE AND CLEANING Inspect the burner before each use of the outdoor gas fireplace The burner must be replaced prior to the outdoor gas fireplace being put into operation if it is evident that the burner is damaged A replacement burner for this outdoor gas fireplace can be obtained by contacting Empire Comfort Systems ...

Страница 11: ...r damaging the outdoor gas fireplace and making it unsafe to operate You should inspect the burner immediately if any of these conditions occur or persist 5 The burner makes popping noises a Check air shutter adjustment b Check burner for clogged ports PLEASE NOTE When ordering parts it is very important that part number and description of part coincide Index Part No Number Description Index Part ...

Страница 12: ...e illustration and list Be sure to give all this information Fireplace Model Number Part Description Fireplace Serial Number Type of Gas Propane or Natural Part Number Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store Order parts through your local dealer Shipments contingent upon strikes fires and all causes beyond our cont...

Отзывы: