background image

CHG/CHR

Page 11

1.

Fireplace won't light when the piezo ignitor is depressed.
a.

With the gas tuned off depress the piezo ignitor to check the
spark. You should see a spark jump from tip of the electrode.
If there is a spark, check the gas supply. Is the tank full? Is
the line purged of air? Can you light the burner with a
match?

b.

Check air shutter adjustment, close as needed.

c.

Check the orifice for blockage.

d.

Is the electrode tip clean and free from debris?

e.

Clean electrode tip.

2.

Burner flame is yellow or orange and there is a smell of gas.
a.

Check the burner inlet for obstructions.

b.

Check the air shutter for proper adjustment.

c.

Check for spiders, spider webs and debris.

3.

Low heat with control knob set on "HI."
a.

Is the fuel hose bent or kinked?

TROUBLE-SHOOTING

If your outdoor gas fireplace does not function properly, use the following checklist for possible solutions.

b.

Is there an adequate gas supply?

c.

Does the orifice or burner need cleaning?

d.

Is the air shutter too far open or closed?

e.

Is the gas supply, or gas pressure low?

4.

The smell of gas with flames appearing sooty yellow.
a.

Check for spiders or insects.

b.

Spiders and insects can nest in the burner and cause a
disruption in the flow of gas from the burner. This is
dangerous and can cause a fire behind the valve cover,
damaging the outdoor gas fireplace and making it unsafe to
operate.
You should inspect the burner immediately if any of these
conditions occur or persist.

5.

The burner makes popping noises.
a.

Check air shutter adjustment.

b.

Check burner for clogged ports.

PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.

Index

 Part

 No.

Number

Description

Index

 Part

 No.

Number

Description

1

R-5647

BOTTOM LOG

2

R-5649

RIGHT CROSS LOG

3

R-5648

LEFT CROSS LOG

4

R-5634

RAIN CAP WITH KNOB AND
HANGER CLIP - RED

4

R-5659

RAIN CAP WITH KNOB AND
HANGER CLIP - GREEN

5

R-5631

CHIMENEA STACK CASTING -
RED

 5

R-5657

CHIMENEA STACK CASTING -
GREEN

6

R-5630

CHIMENEA BODY CASTING -
RED

 6

R-5656

CHIMENEA BODY CASTING -
GREEN

7

R-5651

DOOR SCREEN

8

R-5633

LEG WITH RUBBER FEET - RED
(3 REQ’D)

8

R-5658

LEG WITH RUBBER FEET -
GREEN (3 REQ’D)

9

R-5636

BURNER ASSEMBLY

9.1

R-5909

CAST BURNER ASSEMBLY
WITH PIPE AND VENTURI

9.2

R-5638

VALVE COVER

9.3

    R-5639

ORIFICE - LPG

9.4

    R-5640

ORIFICE - NAT

9.5

    R-5641

SAFETY VALVE

9.6

    R-5642

THERMOCOUPLE

9.7

    R-3992

REGULATOR HOSE ASSEMBLY
- LPG (26")

9.8

    R-2708

PIEZO IGNITOR

9.9

    R-5908

ELECTRODE AND WIRE
ASSEMBLY

9.10

    R-5644

LABEL SET ON CHAIN
(ATTACHED TO VALVE COVER)

9.11

    R-3357

VALVE SPRING

9.12

    R-3358

AIR SHUTTER

9.13

    R-5645

VALVE KNOB

10

    R-5653

TANK SECURING HOOK WITH
BOLT, WASHER AND NUT

NOT SHOWN   R-5635

STACK RESTRICTOR PLATE

NOT SHOWN   R-5646

BURNER MOUNTING BAR

NOT SHOWN   R-5650

FLICKER SHIELD (2 REQUIRED)

NOT SHOWN   R-5913

IGNITOR BRACKET

Содержание CHG

Страница 1: ...his equipment AVERTISSEMENT Si les informations dans ce manuel ne sont pas exactement suivies un feu ou une explosion peut en résulter causant des dommages à la propriété des blessures corporelles ou la mort Ne pas entreposer ou employer de la gazoline ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou tout autre appareil Que faire si vous sentez le gaz N essayer pas d all...

Страница 2: ...ateur pour patio seront exposés à la chaleur radiante et peuvent être endommagés MISE EN GARDE Vous devez utilisez le régulateur de gaz PL de pression à gaz fourni avec ce radiateur pour patio Ce régulateur de gaz PL est réglé pour une pression de sortie de 11 pouces de colonne d eau L alimentation du gaz doit être fermée à la bouteille de gaz PL lorsque ce radiateur pour patio n est pas utilisé L...

Страница 3: ...n of Dangerous Goods Thecylindersupplysystemmustbearrangedforvaporwithdrawal The cylinder used must include a collar to protect the cylinder valve This outdoor gas fireplace shall be used only outdoors in a well ventilated space and shall not be used in a building garage or any other enclosed area If the outdoor gas fireplace is not in use the gas must be turned off at the supply cylinder Storage ...

Страница 4: ...nders after filling Your new outdoor gas fireplace regulator is equipped with a coupling nut Do not attempt to connect any propane cylinder not equipped with a mating Type 1 cylinder valve Connecting the Regulator to the Valve Figure 1 This Type 1 cylinder valve contains a backcheck which is designed to prevent propane from flowing until the valve is properly connecting to a regulator When connect...

Страница 5: ...llation 7 Top 47 from top of unit or 96 from floor Floor Combustible Warning Whenselectingalocationforyouroutdoorchimenea it is important to consider that any ceiling overhang or other surface located above the chimenea can discolor due to heat or carbon particles generated while unit is operating Attention Raincapmustbeplacedonoutdoorchimeneawhen not in use Rain cap will prevent rain from enterin...

Страница 6: ... and 7 8 Holding the burner assembly securely with two hands tip the burner to a position where it will fit through the front door opening The gas inlet plumbing control panel and regulator hose assembly should be pointing to the left and somewhat downasyoumaneuvertheburnerthroughthedoor Guidethe regulator hose and control panel through the large hole in the bottom of the outdoor gas fireplace The...

Страница 7: ... Recesses tabs and holes are provided to locate the logs properly See Figure 10 for proper placement Installation of logs is completed Figure 10 Refer to the following warning Warning Failure to position the parts in accordance with this photograph or failure to use only parts specifically approved with this appliance may result in property damage or personal injury Figure 11 14 Attach the 20 lb L...

Страница 8: ...ch conversion label onto top portion of rating plate 17 Attach 3 8 flared fitting from Natural gas supply line or hose kit onto gas valve 18 Turn on Natural gas supply to outdoor gas fireplace and check all gas connections for leaks with soap solution watching for bubbles on all gas connections 19 The Natural gas inlet supply pressure to the gas valve on outdoor gas fireplace will be from a minimu...

Страница 9: ... an equal amount of liquid detergent and water 6 Apply soap mixture to all gas connections Soap bubbles will appear if there is a leak Tighten connections to make a proper seal If you cannot stop a gas leak turn off the gas supply and call your local gas utility or the dealer from whom the outdoor gas fireplace was purchased Onlythosepartsrecommendedbythemanufacturershould be used on the outdoor g...

Страница 10: ... Close the air shutter to decrease the amount of air to the burner BURNER MAINTENANCE AND CLEANING Inspect the burner before each use of the outdoor gas fireplace The burner must be replaced prior to the outdoor gas fireplace being put into operation if it is evident that the burner is damaged A replacement burner for this outdoor gas fireplace can be obtained by contacting Empire Comfort Systems ...

Страница 11: ...r damaging the outdoor gas fireplace and making it unsafe to operate You should inspect the burner immediately if any of these conditions occur or persist 5 The burner makes popping noises a Check air shutter adjustment b Check burner for clogged ports PLEASE NOTE When ordering parts it is very important that part number and description of part coincide Index Part No Number Description Index Part ...

Страница 12: ...e illustration and list Be sure to give all this information Fireplace Model Number Part Description Fireplace Serial Number Type of Gas Propane or Natural Part Number Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store Order parts through your local dealer Shipments contingent upon strikes fires and all causes beyond our cont...

Отзывы: