Filter Maintenance Record 

Series No.

   

 

 

 

 

 

 

 

          Date:            /        /          ~            /        /   

Morning Afternoon 

Before 

Cleaning

After 

Cleaning 

Week 

H M  Cap. 

Presu.

(Kg)

Air 

Drain 

H M Cap.

Presu.

(Kg)

Air

Drain

Pressure

(Kg) 

Pressure 

(Kg) 

Surface 

Cleaning 

Sign 

Mon. 

 

 

   

 

 

     

 

 

 

Tue. 

 

 

   

 

 

     

 

 

 

Wed. 

 

 

   

 

 

     

 

 

 

Thu. 

 

 

   

 

 

     

 

 

 

Fri. 

 

 

   

 

 

     

 

 

 

Sat. 

 

 

   

 

 

     

 

 

 

Sun. 

 

 

   

 

 

     

 

 

 

 

Series No.

   

 

 

 

 

 

 

 

          Date:            /        /          ~            /        /   

Morning Afternoon 

Before 

Cleaning

After 

Cleaning 

Week 

H M  Cap. 

Presu.

(Kg)

Air 

Drain 

H M Cap.

Presu.

(Kg)

Air

Drain

Pressure

(Kg) 

Pressure 

(Kg) 

Surface 

Cleaning 

Sign 

Mon. 

 

 

   

 

 

     

 

 

 

Tue. 

 

 

   

 

 

     

 

 

 

Wed. 

 

 

   

 

 

     

 

 

 

Thu. 

 

 

   

 

 

     

 

 

 

Fri. 

 

 

   

 

 

     

 

 

 

Sat. 

 

 

   

 

 

     

 

 

 

Sun. 

 

 

   

 

 

     

 

 

 

 

Series No.

   

 

 

 

 

 

 

 

          Date:            /        /          ~            /        /   

Morning Afternoon 

Before 

Cleaning

After 

Cleaning 

Week 

H M  Cap. 

Presu.

(Kg)

Air 

Drain 

H M Cap.

Presu.

(Kg)

Air

Drain

Pressure

(Kg) 

Pressure 

(Kg) 

Surface 

Cleaning 

Sign 

Mon. 

 

 

   

 

 

     

 

 

 

Tue. 

 

 

   

 

 

     

 

 

 

Wed. 

 

 

   

 

 

     

 

 

 

Thu. 

 

 

   

 

 

     

 

 

 

Fri. 

 

 

   

 

 

     

 

 

 

Sat. 

 

 

   

 

 

     

 

 

 

Sun. 

 

 

   

 

 

     

 

 

 

 

Remark:  

1.

 

For Cap., please fill in “High” “Mid.” “Low”. 

2.

 

For Air Drain, please fill in “Much” “Little”. 

Содержание FKH

Страница 1: ...icient Rugged Construction Before beginning operation read this manual carefully Thank you for purchasing this SUPER product Please read this manual carefully in order to ensure that you use the appliance safely and correctly Be sure to keep this manual in a place where it will be easily available for reference OPERATION MANUAL FKH ...

Страница 2: ...yle 2 2 Cautions in Installation 3 3 Warnings in Operation 4 4 Operation 5 5 Maintenance and Repair 5 6 Construction and Parts Table 6 7 Trouble Shooting 7 8 Filter Maintenance Record 8 9 FAQ 9 10 Information Data 10 11 Quality Guarantee 11 ...

Страница 3: ... DIN fitting A ANSI fitting 6 N NBR V VITON E EPDM 7 In Outlet 65 65 x 65mm 50 50 x 50mm 40 40 x 40mm 25 25 x 25mm 6A 65 x 50mm 5A 50 x 40mm 8 FRPP Bracket A B C D FKH 7161 F U J N 65 D 1 2 3 4 5 6 7 8 1 FKH Type 2 Cartridge 4161 4φ x 16 bag 4251 4φx 25 bag 7161 7φx 16 bag 7251 7φ x 25 bag 7321 7φx 32 bag 8161 8φx 16 bag 8251 8φ x 25 bag 3 In Outlet Fitting F Flange U Union 5 U Bag 7 J JIS fitting...

Страница 4: ...ecommend stiff pipes inside the tank 7 Place the machine in an upright position and on a sturdy resting place 8 When the pump inlet and outlet are lower than the liquid level of the tank install valves on the inlet and outlet pipe to prevent siphoning 9 Please make sure that the inlet connecting flange is equal in diameter with the inlet flange and the outlet connecting flange is the same size as ...

Страница 5: ... inside the barrel and may cause an explosion Gaseous chemical element should be let out through the air drain valve If the filter is not to be used for a long time the air drain valve should be kept open to prevent a build up of volatile fumes 6 The flow rate should be checked periodically that to make sure it is normal Clean the medium on a schedule When the pump dry runs for a long time the liq...

Страница 6: ... environment or liquid is harmful to humans please wear protective clothing mask shoes and any other necessary protective devices 8 Make sure the running direction of the motor is correct No fluid will come out of the outlet if it is running in the wrong direction Switching the phase will correct the problem 9 Take the necessary precautions For example make sure that the valves the level of liquid...

Страница 7: ......

Страница 8: ... for leaks There is little outpouring and air is mixed in The liquid tank s pipe is too close to the filter s inlet pipe or the inlet pipe has become loose 1 Keep the tank s pipe farther from inlet pipe 2 Check fix the pipe constantly to avoid air being sucked in Pressure gauge gauge seat is not well sealed Take off the gauge wrap up with tape seal and re install Pressure gauge doesn t work The ga...

Страница 9: ...rnoon Before Cleaning After Cleaning Week H M Cap Presu Kg Air Drain H M Cap Presu Kg Air Drain Pressure Kg Pressure Kg Surface Cleaning Sign Mon Tue Wed Thu Fri Sat Sun Series No Date Morning Afternoon Before Cleaning After Cleaning Week H M Cap Presu Kg Air Drain H M Cap Presu Kg Air Drain Pressure Kg Pressure Kg Surface Cleaning Sign Mon Tue Wed Thu Fri Sat Sun Remark 1 For Cap please fill in H...

Страница 10: ...l if the pressure gets high generally 3 Why the pressure gets high soon Answer Most of capillary on the cartridge is blocked and can not be cleaned Replace a new one 4 Why the cartridge replacing frequently Answer It needs higher pressure to get the liquid runs through the low quality cartridge For high quality cartridge outer capillary is bigger than inner capillary but for low quality cartridge ...

Страница 11: ...rest Power source ______60Hz ______ 50Hz ______1 phase ______3 phase ________ V Composition of solution Solution Temperature Viscosity cP Specific gravity Concentration pH Particles Present ___YES ___NO ___Unknown If Yes Particle Size ___ by Volume _____ Particle Hardness Operating duration hours day Head m Flow rate temperature Place indoor outdoor Piping diameter A Piping length m Discharge side...

Страница 12: ... will charge for repair under the following conditions z The damage is caused by non permitted repair or improper maintenance or operation z The product is broken by natural disasters such as earth quake or fire 3 The consumable parts and accessories are not covered in the guarantee 4 guarantee period 1 year after delivery If you have any question please contact our dealer or Super Giant Enterpris...

Страница 13: ... 82708706 上海區 江蘇省太倉市沙溪鎮岳 王區鎮北路16號 215400 塑寶環保機械 Tel 0512 53303388 53303398 Fax 0512 53303588 總公司 昇展實業股份有限公司 台灣省台南縣永康市中正南路404巷7號 Tel 886 6 2534546 2541601 Fax 886 6 2534226 2420509 While placing your order Please kindly provide us the following information 1 Chemical Name Concentration Temperature Specific Gravity Viscosity 2 Capacity needed __________L min 3 Head needed __________M 4 Power Voltage...