10
Recommended charge temperature range*
0°C to +45°C
Discharging operating temperature range
-10°C to +55°C
Short term (<1 month) storage temperature range
-20°C to +45°C
Long term (>1 month) storage temperature range
-10°C to +20°C
Relative humidity
10-90%
Corrosion
Salt-contaminated atmosphere up to
1 mg salt per m
3
of air, at all relevant
temperatures and humidity conditions.
Applicable to equipment located in open air
and made of material subject to corrosion.
Placement angle (continuously)
Up right
Vibrations and shocks
According UN38.3
Table 7. Environmental conditions
(1) Charging below 0 °C only with reduced charge current. This might result in degraded cycle life.
2.4.1. Marine use
Parameter
Class
Location
Temperature
A
Machinery spaces, control rooms, accommodation, bridge
Humidity
B
All locations except as specified for location A
Vibration
A
On bulkheads, beams, deck, bridge
EMC
B
All locations including bridge and open deck
Table 8. Marine use
2.5. Required tools
•
13mm Hexagon socket wrench
•
Torque wrench
•
TORX key for fuse cover