10
3.5. Connections, indicators and battery controls
1 2 3 4 5 6 7
1 2 3 4
1
2
3
6
4
5
7
8
Figure 2. Connections, indicators and battery controls
1. Con 1 (Output for Bistable Relay; Phoenix FRONT-MC 1,5/4-STF-3,81 1850877)
2. Con 2 (I/O Connection 7; Phoenix FRONT-MC 1,5/7-STF-3,81 1850903)
3. Con 3 (CANopen; 5-pin “micro” style connector)
4. Terminal - (2x M8)
5. Fuse cover
6. Te (2x M8)
7. Reset button
8. Fuse connections
3.5.1. Con 1 (Output for bistable relay)
PIN #
Output range (12V dc)
Function
1
2.7A (continuous)
15A (100ms pulse)
+, OFF
2
2.7A (continuous)
15A (100ms pulse)
-, ON
3
2.7A (continuous)
15A (100ms pulse)
-, OFF
4
2.7A (continuous)
15A (100ms pulse)
+, ON
Table 8. Con1 (Output for bistable relay)
Содержание NOMIA 12V100Ah
Страница 1: ...Manual NOMIA 12V100Ah Version February 2021 ...
Страница 33: ...33 Be in charge Super B ...