![Super B BIB Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/super-b/bib/bib_manual_1401670029.webp)
29
Be in charge.
Super B.
Problem
Possible reason
Solution
Green LED blinking
with short off
intervals
BIB scans for batteries
Wait 10 minutes after booting until
the blinking stops.
Yellow LED blinking
BIB is in pre-charge mode
Configure BIB to ON-state.
BIB has just booted and has not
yet switched the relay
Typically the relay should be enabled
within 5 seconds.
The difference in voltage between
battery bank and charger is too
high to safely switch on the main
relay.
Pre-charge circuit within the BIB
is not capable of pre-charging the
system. Turn off all loads before
switching on the BIB. After the BIB is
turned on, the loads can be enabled.
Yellow LED is on
One or more batteries are
reporting an error.
Determine which battery is reporting
the error. Check for excessive heat,
any damage, short circuits, etc. Take
appropriate safety precautions. If the
problem has been resolved, reset the
system (push button or through the
Super B battery monitor application).
Red LED is on
The BIB cannot find one or
multiple batteries.
Check the CAN cabling and
terminators.
Red LED blinking. 1
flash in 1 second
Battery layout configuration
incorrect
Doublecheck the battery layout.
Does it match completely with the
configuration as stored in the BIB?
The BIB is not
configured (first bootup)
Follow the steps in paragraph 5.2.
Table 12. Troubleshooting