Sunvic SELECT 207 XLS Скачать руководство пользователя страница 6

Select 207 XLS User / Installation Instructions 

 

Page 6 of 8  

Installation Instructions 

 
SELECT 207 XLS Programmer 
 
Technical Data 
 
Power supply:   

230v AC  50Hz. 

Ambient temperature:  Operating 0

°

C to 35

°

Total Input: 

 

6A 

Switch Rating:   

230vAC  6(2)A 

Battery:  

             Never needs replaced 

Wiring:   

 

For fixed wiring only 

Maintenance:   

No user maintenance reqd. 

Disconnection class: 

1B 

 
This unit must be installed by a competent person in accordance with the latest appropriate wiring 
regulations.
 

Pre Installation set-up 
 

Before installing, set the bank of 4 DIP switches 
on the back, to configure the unit according to the 
chart below. 
 
 
 
 
 
 
 
 
 
DIP switches shown in factory default position 
 

Pumped 

– Allows independent control of CH and     

 

     HW. 

Gravity – 

Does not allow CH without HW, but can 

 

    Provide HW without CH. 

24Hr

. -      Runs same programme every day 

5/2 Day

 -   Allows different ON/OFF times at  

                  weekend 

7 Day

 -      Allows different on/off times every day 

 
 
When unit is first switched on, or when the reset 
button is pressed, the status of the DIP switches 
is displayed. 
 
INSTALLATION 
This unit is compatible with many other 
programmers and may be fitted to existing 
standard wall plates. Please consult the 

‘WIRING

 

INTERCHANGE GUIDE’

 for compatible 

programmer types. Some are directly 
interchangeable, others will require minor 
changes to wiring connections. 
Be sure to switch off the mains supply before 
starting. Please read all installation instructions 
before proceeding. 
Ensure that the fixed wiring connections to the 
mains supply, is via a fuse rated at not more  

6 amps, and a class ‘A’ switch, having a contact 
separation of a minimum of 3mm in all poles. 
 
 
 

DIRECT UPGRADE FOR EXISTING PROGRAMMERS 

1.Switch off mains. Loosen 2 securing screws on 
old programmer and unplug it. 
2.Check existing wall-plate has been correctly 
fitted. (See section,Fitting wall plate) 
3.Plug SELECT programmer into wall-plate and 
re-tighten screws. Switch on at mains. 
4.Set timing and programme as detailed in user 
guide 
 

Please note,

 If you wish to change any of the DIP 

switch functions at any time, when the unit is 
replaced back on the wall plate, it will flash the 
latest configuration for 10 secs. and then revert 
back to normal run time. If you don’t want to wait 
for the 10 secs. pressing any button will also take 
the programmer back to the normal run time. 
 
 
FITTING WALL PLATE 
1.Position the wall-plate (terminals along the top   
edge) with 60mm(Min) clearance to its right, 
25mm(Min) above, 90mm(Min) below. Ensure that 
the supporting surface will fully cover the back of 
the programmer. 
2.Ideal location would be 1.4m above floor level, 
easily accessible, reasonably lit and free from 
condensation or temperature extremes. 
3.Fix the wall-plate to a flush mounting single 
conduit box type UA1(BS4662) using M3.5 x 14 
bolts. 
4.Ensure that the wiring to the wall-plate terminals 
leads directly away from the terminals and is 
completely enclosed within the wall-plate 
aperture. Wire ends must be stripped and 
screwed to the terminals, so that minimal bare 
wire is showing. 
 

3 on/offs 

5/2 day 

7 day 

gravity 

2 on/offs 

24Hr

.

 

Pumped 

Содержание SELECT 207 XLS

Страница 1: ...nder the chosen On and Off heating periods or be permanently off The time on the programmer must be correct Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Ti...

Страница 2: ...r mode select buttons are used to set the operating mode for Central heating and Hot water respectively Each has 4 modes as described ON Central heating and or hot water on continuously I E on all the...

Страница 3: ...button will take you to the programme for Saturday and Sunday The ON OFF times can be changed for each day group as above in the changing programme times If you press copy the current programme will...

Страница 4: ...on will give one extra hour of heating Two presses of the button will give two extra hours of heating Three presses of the button will give the maximum of three hours extra heating If the Central heat...

Страница 5: ...selected POWER INTERRUPTION In the event of a mains supply failure the back up battery ensures the programmer continues to keep time and retain your stored programme The screen will go blank but will...

Страница 6: ...sure that the fixed wiring connections to the mains supply is via a fuse rated at not more 6 amps and a class A switch having a contact separation of a minimum of 3mm in all poles DIRECT UPGRADE FOR E...

Страница 7: ...Low Waters Raod Cadzow Industrial Estate Hamilton Tel 01698 812944 ML3 7QU Fax 01698 813637 Tech Helpline 01698 810945 Tech Help Fax 01698 307437 WWW sunvic co uk In the interests of continuous produ...

Страница 8: ...may occur due to various reasons outside of our control Make Model Terminals Sunvic SELECT 207XL N L 1 2 3 4 SP100 SP50 N L 1 4 2 5 SP2 N L 1 4 3 6 Satchwell Libra DHP2201 1 2 8 5 6 3 Satchwell ET140...

Отзывы: