SunTouch TapeMat Installation Manual
19
Ground
Black
Black
Black
White
White
White
Line 1
Load 1
Load 2
Line 2
120 or 240VAC
Sensor Wire
(no polarity)
TapeMat
(maximum 15 amps)
120/240 VAC
SunStat
Two or more
TapeMats
(maximum 15 amps)
Ground
Black
Black
Black
White
White
White
Line 1
Load 1
Load 2
Line 2
Sensor
W
ire
(no polarity)
120/240 VAC
SunStat
120 or 240VAC
120/240VAC Control Wiring Diagrams
Typical Wiring for multiple
Tapemats with SunStat
Control (120/240VAC)
20-amp circuit.
Note:Allelectricalworkmustbedonebyaqualifiedlicensed
electricianinaccordancewithlocalbuildingandelectri-
calcodes,andtheNationalElectricalCode(NEC),espe-
ciallyArticle424oftheNEC,ANSI/NFPA70andSection
62ofCECPart1.
!
CAUTION
Makesure120VACissupplied
to120VACmatsand240VAC
issuppliedto240VACmats.
Otherwise,dangerousoverheating
andpossiblefirehazardcanresult.
Ground
Black
Black
Black
White
White
White
Line 1
Load 1
Load 2
Line 2
120 or 240VAC
Sensor Wire
(no polarity)
TapeMat
(maximum 15 amps)
120/240 VAC
SunStat
Two or more
TapeMats
(maximum 15 amps)
Ground
Black
Black
Black
White
White
White
Line 1
Load 1
Load 2
Line 2
Sensor
W
ire
(no polarity)
120/240 VAC
SunStat
120 or 240VAC
Typical Wiring for one
TapeMat with SunStat
Control (120/240VAC)
20-amp circuit.