7
3.3 Illustration of Wall mounting and pipe mounting
3.4 Assembly of electrode and housing
3.4.1 Cable set-up:
a.
Make sure to remove the conductive rubber or aluminum-foil paper between the electrode
signal wire and the network cable.
b. Extend the cable to the controller without any joint except specific junction box. Connect
Set-up diagram of coaxial cable:
See the correct set-up method on the left:
Note: The black conductive rubber covering
on the central spindle should be removed for
use.
Installation of pipe mounting
Fixed with U-shaped pipe clip
Order No.: 8-34
Installation of wall mounting
Fixed with 4 M5
screws
Rain covered
Order No.: 8-34 and 8-35
Figure 3
Remove the conductive rubber
Rain covered
Order No.: 8-35