Doc. Title
ST940 User Manual
Concerning:
Rev.
Date (dd-mm-yy)
Page of Pages
Features and how to configure ST940
1.19
0
19-06-15
15
20 of 51
“Location”, ”Emergency” and “Alert” reports.
MAGNET_ALERT
‘0’ / ‘1’
0 : Disable Alert
1 : Enable Alert
VI_ON_THRES
String
1/255G
Threshold value for Motion Virtual Ignition On
0 : Disable the Motion checking
Range : 3~50
Default : 5
VI_ON_DELAY
String
Second
Delay time for Motion Virtual Ignition On
Range : 3~300
Default : 10
VI_ON_PERCENT
String
%
Percent for Motion Virtual Ignition On
Range : 30~100
Default: 70
VI_OFF_THRES
1/255G
Threshold value for Motion Virtual Ignition Off
Range : 3~50
Default : 5
VI_OFF_DELAY
String
Second
Delay time for Motion Virtual Ignition Off
Range : 3~300
Default : 10
VI_OFF_PERCENT
String
%
Percent for Motion virtual Ignition Off
Range : 30 ~ 100
Default : 70
DEEP SLEEP
‘0’ or ‘1’
0 : Disable
1 : Enable
<Example>
[command] ST910;SVC;123456789;0,0;1;5;10;70;5;10;70;0;0
[command] ST910;SVC;
456789
;0;0;1;5;10;70;5;10;70;0;0
[response] ST910;RES;SVC;123456789;0,0;1;5;10;70;5;10;70;0;0
[response] ST910;RES;SVC;
456789
;0,0;1;5;10;70;5;10;70;0;0
<Notes>