IGNDET_L
String
In case of virtual ignition, the asset can recognize
parking state when asset power is less than IGNDET_L.
Default = ‘0’
<example>
[command] ST3330MBV;850000;02;10.5;22;19;8.00;18.00;0;0
[response] ST3330MBV;Res;850000;122;10.5;22;19;8.00;18.00;0;0
<note>
IGNDET_H and IGNDET_L are ‘0’, device check parking and driving automatically.
4-8. Set Parameters of Motion Sensor
HDR
DEV_ID
VER
CHR_STOP_THRES_12
DECIDE_BAT_12
OPERATION_STOP_THRES_12
IGNDET_H
IGNDET_L
VI_ON_THRES
VI_ON_DELAY
VI_ON_PERCENT
VI_OFF_THRES
VI_OFF_DELAY
VI_OFF_PERCENT
● Definition
: Set motion sensor parameters
Field
Definitions
Unit
Remark
HDR
“ST3330MSR”
Command type
DEV_ID
6 char.
Device ID
VER
“02”
Protocol Version
SHOCK_DELAY
String
Sec.
Delay for entering shock detection mode after ignition off
0 – Disable
Range : 1 ~ 21600 (5hour)
Recommend : 600 ( 10 min.)
MOTION_THRES
String
Step
Detection level of shock violation.
Range : 0.04 ~ 2.0
Recommend : 0.04
SHOCK_THRES
String
Step
Detection level of shock violation.
Range : 0.04 ~ 2.0
Recommend : 0.04
COLL_THRES
String
Step
Gravity for collision report.
Range : 0.1 ~ 2.0
Recommend : 0.7
VI_ON_THRES
String
1/255G Threshold value for Motion Virtual Ignition On
Range : 3~50
Default : 5