![SunTech ST3330 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/suntech/st3330/st3330_user-manual_1400861017.webp)
ST3330 User Manual
17
reached to server and sends the data again.
Examples of ACK report
are as below.
String Format : “
ST3330ACK
;850000”
Zip Format :
0x15
0x85 0x00 0x00
It is recommended ACK_TYPE is set to ‘1’ to confirm all data can be transmitted safely.
Report Type
UDP_ACK=0
UDP_ACK=1
UDP_ACK=2
UDP_ACK=3
Alive
X
X
X
X
STT
X
O
X
X
Event, Alert, Etc.
X
O
O
X
Emergency
X
O
O
O
4-7. Set Parameters of Main Voltage
HDR
DEV_ID
VER
CHR_STOP_THRES_12
DECIDE_BAT_12
OPERATION_STOP_THRES_12
IGNDET_H
IGNDET_L
● Definition
: Set some value of main voltage.
Field
Definitions Remark
HDR
“ST3330MBV” Command type
DEV_ID
6 char.
Device ID
VER
“02”
Protocol Version
CHR_STOP_THRES_12
String
Voltage value to stop backup battery charging in 12V
asset.
DECIDE_BAT_12
String
Voltage value to check whether the asset’s battery is 12V.
OPERATION_STOP_THRES_12
String
Voltage value to protect asset battery.
The device operation stops if car battery voltage is lower
than this value in asset that has 12V power.
IGNDET_H
String
In case of virtual ignition, the asset can recognize driving
state when asset power is more than IGNDET_H.
Default = ‘0’