<example>
[command] ST3330EVT;850000;02;1;60;0;3;2;2;30;20;20;1;0;1;0;0;0;0;0;0;0;0;0;0;0;0
[response] ST3330EVT;Res;850000;010;1;60;0;3;2;2;30;20;20;1;0;1;0;0;0;0;0;0;0;0;0;0;0;0
<notes>
** If IGNITION is set to ‘0’, device doesn’t check driving or parking state of the asset. It reports status string
with idle mode always, and cannot support parking lock and the service that enters sleep or deep sleep
automatically when the asset is parked.
** If IGNITION is set to ‘2’, the device checks driving or parking state of the asset with voltage range of
asset’s battery. We named it as ‘Virtual Ignition’. Virtual ignition can operate when the device installed into
real asset and it may be need adjustment of voltage range for special asset. For setting method, please
refer 6.3.
** In case of pulse, pulse time may have tolerance about dozens of ms.
** Immobilizer, LED Blink line and Buzzer type cannot set both OUT1 and OUT2 simultaneously.
** In case that a event is set to “door sensor”, active state means door is opened.
** If device has the Handsfree kit, e
ach time the volume up button is pressed once, the speaker volume is turned up as below.
0 -> 1 -> 2 -> 3 -> 4 ->5 ->0 -> 1 -> 2 ->3 -> 4 -> 5 - > 0 -> 1 -> ….
(0 : Volume mute, 5 :Max Volume)
Type of no supported event line is fixed to “No Use”.
Below table is for example of 4 line event model.
Field
Definitions
Unit
Remark
HDR
“ST3330EVT”
Command type
DEV_ID
6 char.
Device ID
VER
“02”
Protocol Version
IGNITION
‘0’ ~ ‘2’
Ignition using state
0 : Not use ignition
1 : Use ignition Line
2 : Virtual ignition(power)
3 : Virtual ignition (motion)
T1
String
Sec
Delay for entering idle mode after ignition goes to off
T2
String
Sec