ST3330
User Manual
Suntech International Ltd.
Страница 1: ...ST3330 User Manual Suntech International Ltd...
Страница 2: ...ntil A1 times or receiving server acknowledge 2 2 Report AVL reports GPS and some information at predefined interval depending on the current modes Also AVL sends some alerts for example movement at t...
Страница 3: ...A When Firmware of device has some error or has to be changed for a new service to be implemented device can update internal ROM file by over the air FOTA remotely via WCDMA Customers do not need to v...
Страница 4: ...m device is ended by r 0x0D Command message format from server to device HDR DEV_ID VER Field 1 Field 2 Field n Field Definitions Remark HDR String ST3330 Command type DEV_ID 6 char Device ID of AVL V...
Страница 5: ...ion 0 PAP NO in Synctrack 1 CHAP YES in Synctrack A Automatic WCDMA set In this case parameters in APN USER_ID and USER_PWD field should be empty APN String Access Point Name USER_ID String ID for WCD...
Страница 6: ...USER_ID and USER_PASS to empty And the device reports response string after adding real WCDMA parameters when automatic WCDMA set is selected 4 2 Report Parameter Setting HDR DEV_ID VER T1 T2 T3 A1 S...
Страница 7: ...g mode SMS_T2 String Min Interval for sending status report in driving mode SMS_PACK_NO String Report No in one SMS message ANGLE_RPT String Degree Report STT message if it s greater than ANGLE_RPT 0...
Страница 8: ...sion T1 String Sec Delay for entering idle mode after ignition goes to off T2 String Sec Delay for entering active mode after ignition goes to on IN1_TYPE 0 7 0 Falling Edge 1 Rising Edge 2 Both Edge...
Страница 9: ...1 is active PULSE1_NO String Pulse number when out1 type set to pulse Range 0 9999 If pulse no is 9999 pulsing runs permanently PULSE1_ON String 100ms Active time of pulse1 Range 0 9999 It should be s...
Страница 10: ...pecial asset For setting method please refer 6 3 In case of pulse pulse time may have tolerance about dozens of ms Immobilizer LED Blink line and Buzzer type cannot set both OUT1 and OUT2 simultaneous...
Страница 11: ...7 7 No Use OUT1_ACTIVE 0 or 1 PULSE1_NO 0 PULSE1_ON 0 PULSE1_OFF 0 BAUD 0 0 No use example command ST3330EVT 850000 02 1 60 0 3 2 2 30 20 20 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 response ST3330EVT Res 85000...
Страница 12: ...har Phone number for SMS commands IN_CALL_LOCK 0 or 1 Lock of Incoming Call Disable 0 Enable 1 If enabled only call from CALL_MT1 MT5 number can be accepted CALL_MT1 String Up to 20 char Phone number...
Страница 13: ...boundary or starts moving over some velocity the device reports parking lock emergency SPEED_LIMIT String Km h Over speed limit If 0 the device does not check over speed If 1 and the asset runes over...
Страница 14: ...30SVC Res 850000 010 1 120 0 0 0 0 1 1 1 0 0 0 0 0 0 0 0 0 notes Function of M_SEMSOR can be used with the model that has motion sensor If shock or collision detection is enabled device will report to...
Страница 15: ...AM_CHK_TM are assist for jamming detection to avoid false detection At least we recommend use JAM_CHK_DIST for safety If you use two assist functions it can detect two case of jamming as follows Case...
Страница 16: ...UDP server is used If 0 or empty the device would use port 9000 If not zero the device can receive commands with port DEV_PORT Reserved 0 Reserved 0 Reserved 0 Reserved 0 Reserved 0 Reserved 0 example...
Страница 17: ...OPERATION_STOP_THRES_12 IGNDET_H IGNDET_L Definition Set some value of main voltage Field Definitions Remark HDR ST3330MBV Command type DEV_ID 6 char Device ID VER 02 Protocol Version CHR_STOP_THRES_1...
Страница 18: ...ON_DELAY VI_ON_PERCENT VI_OFF_THRES VI_OFF_DELAY VI_OFF_PERCENT Definition Set motion sensor parameters Field Definitions Unit Remark HDR ST3330MSR Command type DEV_ID 6 char Device ID VER 02 Protocol...
Страница 19: ...rcent for Motion virtual Ignition Off Range 30 100 Default 70 example command ST3330MSR 02 600 0 04 0 04 0 7 5 10 70 5 10 70 response ST3330MSR Res 852588 128 600 0 04 0 04 0 70 5 10 70 5 10 70 notes...
Страница 20: ...000 029 000 00 7 1 0 15 33 100000 2 0002 4 11 2 Reset Definition Reset all of parameters Field Definitions Unit Remark CMD_ID Reset Reset Initialize all parameters with factory value and reboot the d...
Страница 21: ...0 0 1 1 1 0 0 0 0 DEV 0 0 0 0 notes After power on device sends response string of preset once DEV filed informs current status of device as below OUT1 0 Disable 1 Enable OUT2 0 Disable 1 Enable PWR_...
Страница 22: ...ckup battery is connected TRACKING 0 Stop Tracking 1 Start Tracking Anti Theft 0 Disable 1 Enable Reserved Reserved 4 11 4 ACK of Emergency Definition Stop emergency report Field Definitions Unit Rema...
Страница 23: ...t automatically 4 11 6 Disable1 Definition Inactive Output1 Field Definitions Unit Remark CMD_ID Disable1 Disable Output1 example command ST3330CMD 850000 02 Disable1 response ST3330CMD Res 850000 010...
Страница 24: ...ons Unit Remark CMD_ID ReqVer Request device version Device reports Model Buyer Protocol and S W release version example command ST3330CMD 850000 02 ReqVer response ST3330CMD Res 850000 010 ReqVer ST3...
Страница 25: ...number Field Definitions Unit Remark CMD_ID InitMsgNo Set message number to 0 example command ST3330CMD 850000 02 InitMsgNo response ST3330CMD Res 850000 010 InitMsgNo 4 11 23 Reboot Definition reboo...
Страница 26: ...ST3330 User Manual 26 example command ST3330CMD 850000 02 ReqSIMIP response ST3330CMD Res 850000 010 ReqSIMIP 172 16 18 6...
Страница 27: ...3330 User Manual 27 3 Installation 3 1 Insert SIM card 3 2 Backup battery The backup battery should be used when main power is cut off 3 3 Install The Device is fixed to the asset 3 4 Assemble as belo...
Страница 28: ...by the Suntech Caution Use the company designated by Suntech for charging and device setting 3 5 Check GPS WCDMA operation and battery charger operation with LEDs It takes 3 10 minutes for GPS connect...
Страница 29: ...g 2 SIM is blocked about WCDMA using 3 Temporary network barrier 4 Weak WCDMA signal 5 WCDMA antenna connection is not firm No Network 4 Possible Cause 1 WCDMA antenna is disconnected 2 WCDMA antenna...
Страница 30: ...sure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 cen...