background image

5

ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ

ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ

 

     

INSTALLATION and OPERATION MANUAL

                     

     INSTALLATION and OPERATION MANUAL

 

     

INSTALLATION and OPERATION MANUAL

                     

     INSTALLATION and OPERATION MANUAL

1. MAIN INSTRUCTIONS AND WARNINGS

i

Before starting the installation 

process, read the entire 

instruction.

i

The installation of the appliance 

should strictly follow the 

instructions, otherwise the 

warranty will expire.

Any modification or replacement 

of the original parts with 

others automatically cancels 

the warranty given by the 

manufacturer. Using the 

appliance in environments and 

conditions different from those 

described in this manual will 

automatically invalidate any 

submissions of  claims.

Incorrect performance of 

electrical binding, which does not 

coincide with good practice, can 

lead to a injury.

Electrical connection must 

be carried out by a qualified 

electrician.

The device should not be placed 

in an aggressive environment 

that could damage it (dusty 

rooms, explosive substances in 

the air, open air, etc.).

To the inlet of the water reservoir, 

a 0.8 MPa (8 bar) safety valve 

must be secured to ensure that 

the pressure does not exceed the 

rated pressure. It is forbidden 

to put a stop valve between the 

water tank and the safety valve.

The water heater is intended for 

the storage of drinking water so it 

must comply with the applicable 

national drinking water 

regulations or in case of failure 

the warranty must be cancelled.

The device should never to 

working without water in the 

water tank.

The power cord has a standard 

plug that must be plugged into 

a standard outlet (16A; 230V). 

The socket must have a separate 

supply from the electrical chain 

and there should be no other 

connected consumers in that 

circuit.

The water from the water tank is 

drained through the cold water 

inlet. To this end, it is necessary 

to provide a crane for the 

installation.

To ensure the correct operation of 

the safety valve, periodic annual 

inspections of the safety valve 

must be carried out. If necessary, 

clear it from limestone and make 

sure it is not blocked.

The device can be used by 1 

person who is familiar with 

 

instruction. Children over 8 years 

of age and people with disabilities 

may use the appliance only under 

the supervision of an instructed 

person.

During work it is forbidden to 

move lifting, cleaning or repairing 

the device.

The installation of the appliance 

must be carried out according 

to the standards in force by an 

authorized specialist.

Содержание TDA 200

Страница 1: ...HEAT PUMP FOR DOMESTIC HOT WATER DHW serie TDA TECHNICAL PASPORT INSTALLATION AND OPERATION MANUAL Versie 0 2...

Страница 2: ...2 INSTALLATION and OPERATION MANUAL...

Страница 3: ...F THE HEAT PUMP 6 3 TRANSPORTATION OF THE THERMO PUMP TDA 6 4 SUBJECT OF DELIVERY 7 5 TECHNICAL DESCRIPTION OF THE PRODUCT 7 6 INSTALLATION THE THERMO PUMP TD 8 7 CONTROLLER 14 8 TECHNICAL PARAMETERS...

Страница 4: ...n the TDA model provides the possibility of using independent heat sources The instruction describes the process of installing and servicing the product Installation and connection may only be carried...

Страница 5: ...stop valve between the water tank and the safety valve The water heater is intended for the storage of drinking water so it must comply with the applicable national drinking water regulations or in ca...

Страница 6: ...igence or lack of protection from harmful external influences The device should not be locked or objects placed on it If the temperature exceeds 85 degrees during operation contact a workshop immediat...

Страница 7: ...vironment 5 2 Water tank The TDA water tank is a steel tank for do mestic hot water The water purity and protection of the metal from the corrosive action of the water is ensured by a uni form titaniu...

Страница 8: ...PUMP TDA The minimum height of the room in which the thermodynamic boiler can be in stalled is 2000 mm for TDA E200 and TDA S200 models 2300 mm for TDA E300 and TDA S300 The product is designed to dra...

Страница 9: ...NUAL P D Z E A Si So R Z B H1 H H V V 3 0 7 5 Z E L Si So H H1 A Si So R Z B Z E P D H V V 3 0 7 5 Z E L Si So Sheme 4 Mounting dimensions of model TDA 200 Sheme 5 Mounting dimensions of model TDA 300...

Страница 10: ...150 150 Hot water outlet B mm Rp 1 990 1260 El bindings E mm 1092 1362 Electric heating anode U P mm Rp 11 4 180 700 720 Recirculation R mm Rp 3 4 785 1000 Inlet coil Si mm Rp 1 635 635 Outlet coil So...

Страница 11: ...ION and OPERATION MANUAL Sheme 7 Suction and blowing air to a neighboring room Scheme 8 Suction and outlet of air in the same room Scheme 9 Suction and blowing air to a neighboring room Sheme 10 Sucti...

Страница 12: ...Inlet water B DHW C Recirculation D Draining water 1 Water Heater 2 Circulation group expansion vessel for a solar system 3 Coil type heat exchanger 4 El Heater 5 Built in heat pump 6 Solar collectors...

Страница 13: ...the anode is installed during installation The connection schemes in this manual are exemplary When connecting the product to a solar system or boiler it is necessary to consult and supervise a techn...

Страница 14: ...am 1 Compressor 2 Fan 3 Compressor condenser 4 Pressostat 5 Temperature sensor for water 7 El power supply 11 Temperature sensor evaporator 13 El PV terminal 15 Electromagnetic valve 16 Fan socket 17...

Страница 15: ...splay 3 Quick button P to change the operating mode 4 Quick button HT for thermal disinfection protection against legionella and rapid heating 5 HT indicator for thermal disinfection or rapid heating...

Страница 16: ...ower than the set minimum temperature L1 the appliance automatically switches to heater mode with electric heater flashes lit 6 The appliance is in automatic mode and the water is heated by the heat p...

Страница 17: ...s not affect the operation 3 Heat pump water heating and automatic backup heat switching program P5 when the evaporator temperature is too low The heat pump operates completely independently with prio...

Страница 18: ...is not completed iThe indicator lights during the temperature disinfection i IMPORTANT In case the program is not executed for 12 hours the function stops and switches to normal operating mode 5 Fast...

Страница 19: ...pressing the buttons and after which the same buttons can be used to toggle be tween parameters When the desired parameter is selected you must wait for 8 seconds for the dis play to show the perimet...

Страница 20: ...cooling system Make sure the water tank is full of water You can clear the error by pressing the button If it appears again contact your service center Alternative 8 and The DHW sensor is not connect...

Страница 21: ...21 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL 8 TECHNICAL PARAMETERS OF THERMO PUMP TDA...

Страница 22: ...rating range Air temperature min max 70 350 70 350 Water temperature min inlet max outlet 100 600 100 600 Refrigeration circuit Refrigerant type R134a R134a Refrigerant quantity 1 3 kg 1 3 kg Heatsour...

Страница 23: ...water outlet B mm Rp1 990 Rp1 1260 Flange O mm 180 Rp11 4 700 Rp11 4 720 Anode P mm Rp11 4 700 Rp11 4 720 Recirculation R mm Rp3 4 785 Rp3 4 1000 Drain sleeve Y mm Rp1 30 Rp1 30 Heat exchanger coils S...

Страница 24: ...tion of magnesium anode and pe riodic replacement Check the safety of the valve system Check the coolant charge Check that the service flange bolts and the boiler water connections are loose 10 RECYCL...

Страница 25: ...Directive 2006 42 EC of 17 May 2006 on the essential requirements and assessment of conformity of machinery European Parliament Council Directive 2004 108 ECof15December2004onthe approximation of the...

Страница 26: ...26 INSTALLATION and OPERATION MANUAL...

Страница 27: ...27 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL...

Страница 28: ...ISO 9001 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg...

Отзывы: