3.4.
Thermostat
Included at standard water tank package.
The thermostat may be adjusted by the user within the range 30°С ÷ 80°С, and the thermal protection would
go off in case the water reaches 95°С.
This is an adjustable double THERMOSTAT which is designed to regulate the water temperature and ensures
safety tolerance; it can be manually adjusted (TLSC model) or automatically adjusted (TLSC/A model).
Fig 1
CONFORMITY TO STANDARDS
This product is in conformity with:
- EN 60730-1 and subsequent editions;
- EN 60730-2-9
CONFORMITY TO REGULATIONS
This product complies with:
- Low Voltage Directive 73/23 EEC
- Electromagnetic Compatibility Directive
89/336/EC
TECHNICAL CHARACTERISTICS
Temperature range – regulation- 0°C ÷ 90°C;
limit - 90°C ÷ 110°C;
Tolerance
Regulation ± 5k,
limit – 15 k; -6 k (depends on the type)
Temperature differential
Regulation 6 ± 2 k; 4 ± 1 k (depends on the type)
Limit 25 ± 8 k; 15 ± 8 k (depends on the type)
Automatic adjustment (TLSC/A) and
manual adjustment (TLSC).
Degree of protection
= IP 40
Insulation class = I.
Temperature change rate = <1К/min.
Maximal temperature point: 80°C
Maximal temperature for electric lamp:
125°C
Accumulation temperature: 15°C ÷ 55°C
Maximum pressure of the cartridge: 10
bar
Constant time: < 1“
Electric connection
:
C-1 ADJ.:10(2,5)A/250V°;
C-2 ADJ.:6(2,5)A/250V~;
C-1LIM.:0,5A/250V~;
C2LIM.:10(2,5)A/250V~;
Terminal – circuit breaker or
switch-on contacts.
Switch-on action – 2B.
Place of installation – normal.
Type of wire – M20 x 1.5.
WARNING !
All installation operations, including manual adjustments, must be fulfilled by a