INSTALLATION and OPERATION MANUAL 

 
 
 

3.

 

Description of water tank 

Hygienic Combi tanks are used To produce  and  accumulate  sanitary  hot  water  and  hot  water  for  space-
heating  system.    
Coil-in-Tank construction- Flexible stainless-steel coil for sanitary hot water +Buffer tank powering space-
heating system. Sanitary water heats up instantaneously as it flows through the large surface stainless coil. 
Thus water is delivered hot while still fresh and clean of depositions. 
 

HYG series

 -Inlet/Outlet arrangement –180 angle degrees. 

HYG-B series

 -Inlet/Outlet arrangement –90 angle degrees. 

 

HYG /HYG -B 

models, the heat source is an electric heater. 

HYG R/ HYG-BR

 models have a built-in heat exchanger (coil type) designed to connect to a solar installation or 

boiler. Option for installation of an electric heating element. 

HYG R2 / HYG-BR2 

models have two built-in heat exchanger (coil type) for connection to the solar system and 

boiler. Option for installation of an electric heating element. 
 
 

3.1.

 

Removable  insulation and outer casing 

The quality of the insulation of a water heater is a key factor for its heat conservation capability and energy 
efficiency. 
All 

Hygienic Combi tanks HYG series/HYG-B series 

have Removable insulation with thickness 100 mm (DIN 

4753, part 8) and outer casing of PVC with RAL 9006 color. 
 
 

3.2.

 

Water tank 

Floor standing. Water tank is made of low-carbon steel  S235JR,  
DHW tube of sanitary grade stainless steel -316L, heats up instantaneously. 
All threads are internal  (see technical parameters).   
 
 

3.3.

 

Electric heating element  
 

Outlet connection of electric heating element 1 ½“ :  
3000W/230V; 4500W/230V; 6000W/230V; 7500W/400V.  
 
 
 
 

Water tank 

Capacity, L 

Connection 

 

Length 

L, mm

 

Current, 

Voltage, 

500 

1 ½“

 

410 

6000 

230/400 

800÷ 1500 

1 ½“

 

590 

7500 

230/400 

In the table of technical parameters is specified location for installation of electric heating element 
 

 

The connection of the electric heating element to the electric power supply must be 
done by a qualified electricians.  
When connect the heating element to the electric network, make sure that it is properly 
grounded. 

Содержание HYG 1000/33

Страница 1: ...L 500 800 1000 1500 HYG HYG B without coil HYG R HYG B R with one coil HYG R2 HYG B R2 with two coils model serial No NES New Energy Systems Ltd 12 Madara Blvd Shumen 9700 Bulgaria tel 359 54 874 555...

Страница 2: ...room 1 2 Requirements for installation 3 2 Description 2 1 Insulation and outer casing 2 2 Water tank 2 3 Electric heating element 2 4 Thermostat 4 4 4 5 5 3 Connecting of safety relief valve to water...

Страница 3: ...the stability of the floor of the room where it will be installed regulations and norms concerning the fitting of theinstallation with safety devices safety during installation personal protective eq...

Страница 4: ...installation of an electric heating element 3 1 Removable insulation and outer casing The quality of the insulation of a water heater is a key factor for its heat conservation capability and energy ef...

Страница 5: ...4 INSTALLATION and OPERATION MANUAL Wiring diagrams...

Страница 6: ...TERISTICS Temperature range regulation 0 C 90 C limit 90 C 110 C Tolerance Regulation 5k limit 15 k 6 k depends on the type Temperature differential Regulation 6 2 k 4 1 k depends on the type Limit 25...

Страница 7: ...remove the front part of the thermostat Unravel the power supply wires and connect them to the terminals of the thermostat Figure 5 following the instructions fig 5 NOTE See Figure 6 To close the fron...

Страница 8: ...Buffer tank Legend 1 Heating system 2 Tee 3 Safety relief pressure valve 4 Heat carrier inlet 3 2 Connecting of Stainless HYG coil Legend 1 Cold water inlet water supply 2 Check return valve 3 Tee 4...

Страница 9: ...r C 3 95 3 95 3 95 3 95 Operating pressure Max DHW tube temp bar C 6 95 6 95 6 95 6 95 Continuous outflow 10 45 C when the bufferis charged to 65 C L h 1080 1400 1840 2800 Continuous outflow 10 38 C w...

Страница 10: ...1700 Air vent sleeve F mm G1 1610 G1 1860 G1 2040 G1 2170 Boiler heat carrier inlet G mm G1 1370 G1 1573 G1 1742 G1 1808 Sleeve H mm G1 1270 G1 1389 G1 1521 G1 1653 Sensor sleeve I mm G 1120 G 1290 G...

Страница 11: ...temp bar C 16 110 16 110 16 110 16 110 Operating pressure Max buffer temp bar C 3 95 3 95 3 95 3 95 Operating pressure Max DHW tube temp bar C 6 95 6 95 6 95 6 95 Continuous outflow 10 45 C when the b...

Страница 12: ...leeve F mm G1 1610 G1 1860 G1 2040 G1 2170 Boiler heat carrier inlet G mm G1 1370 G1 1573 G1 1742 G1 1808 Sleeve H mm G1 1270 G1 1389 G1 1521 G1 1653 Sensor sleeve I mm G 1120 G 1290 G 1450 G 1525 Sle...

Страница 13: ...1 8 11 1 2 0 12 3 2 4 14 8 Operating pressure Max coil temp bar C 16 110 16 110 16 110 16 110 Operating pressure Max buffer temp bar C 3 95 3 95 3 95 3 95 Operating pressure Max DHW tube temp bar C 6...

Страница 14: ...G1 1860 G1 2040 G1 2170 Boiler heat carrier inlet G mm G1 1370 G1 1573 G1 1742 G1 1808 Upper coil inlet S2 sleeve H mm G1 1270 G1 1389 G1 1521 G1 1653 Sensor sleeve I mm G 1120 G 1290 G 1450 G 1525 U...

Страница 15: ...pressure Max buffer temp bar C 3 95 3 95 3 95 3 95 Operating pressure Max DHW tube temp bar C 6 95 6 95 6 95 6 95 Continuous outflow 10 45 C when the bufferis charged to 65 C L h 1080 1400 1840 2800...

Страница 16: ...er intlet H mm G1 775 G1 845 G1 930 G1 1045 Boiler heat carrier Electric heating element I mm G1 900 G1 930 G1 1050 G1 1280 Sensor sleeve K mm G 1140 G 1160 G 1320 G 1520 Sensor sleeve L mm G 1420 G 1...

Страница 17: ...rating pressure Max coil temp bar C 16 110 16 110 16 110 16 110 Operating pressure Max buffer temp bar C 3 95 3 95 3 95 3 95 Operating pressure Max DHW tube temp bar C 6 95 6 95 6 95 6 95 Continuous o...

Страница 18: ...rier intlet Lower coil S1 H mm G1 775 G1 845 G1 930 G1 1045 Boiler heat carrier Electric heating element I mm G1 900 G1 930 G1 1050 G1 1280 Sensor sleeve K mm G 1140 G 1160 G 1320 G 1520 Sensor sleeve...

Страница 19: ...l capacity m 2 L 1 0 6 2 1 8 10 46 1 71 10 5 2 0 12 1 Operating pressure Max coil temp bar C 16 110 16 110 16 110 16 110 Operating pressure Max buffer temp bar C 3 95 3 95 3 95 3 95 Operating pressure...

Страница 20: ...845 G1 930 G1 1045 Boiler heat carrier Electric heating element I mm G1 900 G1 930 G1 1050 G1 1280 Heat carrier outlet Upper coil S2 J mm 360 23 2 G1 1050 G1 1210 G1 1405 Sensor sleeve K mm G 1140 G 1...

Страница 21: ...be with or without insulation They are secured on a pallet packed with foil Insulation decorative cover and rosettes can be delivered separately Advantages Easy transportation takes less space at tra...

Страница 22: ...rth in product manuals or use of water with characteristic values exceeding Dissolvable salts 500 mg l Calcium carbonate 200 mg l Free carbon dioxide 50 mg l ph content minimum 5 and maximum 12 5 Free...

Страница 23: ...ims for this reason the customer shall not make any changes in installation conditions which are reasons for the claim without prior written consent of the Technical Department 4 Limitation of liabili...

Отзывы: