background image

 

4.  BATTERY TESTING EQUIPMENT AND CONDITIONS 

 

4.1.  Appearance 

 
There  shall  be  no  such  defect  as  scratch,  bur  and  other  mechanical  scratches,  and  the 
connector should be no rust dirt. For the structure and dimensions, see the attached drawing 
of the battery. 
 

4.2.  Measurement Apparatus 

 

1. Dimension Measuring Instrument 

The  dimension  measurement  shall  be  implemented  by  instruments  with  an  equal  or  more 
precision scale of 0.01mm. 
 

2. Voltmeter 

The  standard  class  specified  in  the  national  standard  or  more  sensitive  class  has  inner 
impedance less than 10 KΩ/V. 
 

3. Ammeter 

Standard  class  specified  in  the  national  standard  or  more  sensitive  class.  Total  external 
resistance, including ammeter and wire, is less than 0.01Ω. 
 

4. Impedance Meter 

Impedance  shall  be  measured  by  a  sinusoidal  alternating  current  method(AC  1kHz  LCR 
meter). 
 
 

4.3.  Standard Test Condition 

The  test  should  be  conducted  with  new  batteries  within  one  month  after  shipment  from  our 
factory, and the cells shall not be cycled more than five times before the test. Unless otherwise 
defined,  test  and  measurement  shall  be  done  under  a  temperature  of  23±2

  and  relative 

humidity of less 75%, air 86Kpa~106Kpa. 
 

4.4.  Rest Period 

Unless otherwise defined, 30min, rest period after charge, 30min, rest period after discharge. 
 

Содержание SSCLK3.1

Страница 1: ...attery SSCLK3 1 SSCLK5 6 Global Tech China Ltd 3 Floor Wai Yip Industrial Building 171 Wai Yip Street Kwun Tong Kowloon Hong Kong Tel 852 2884 4318 Fax 8522884 4816 www sunsynk com sales globaltech ch...

Страница 2: ...OVALS AND CERTIFICATES 13 9 APPROVALS AND CERTIFICATES 14 9 1 LONG TIME STORAGE 14 9 2 OTHERS 14 10 WARRANTY 14 10 1 WARRANTOR 14 10 2 PRODUCTS 14 10 3 PRODUCT WARRANTY 14 10 4 PERFORMANCE WARRANTY 15...

Страница 3: ...ne week of shipment with less than 5 cycles Dimension Depth 24 5mm 24 5mm Initial dimension Width 140 5mm 140 5mm Height 160 5mm 160 5mm Rapid charge based on cell voltages Constant Current 110A 110A...

Страница 4: ...RY CELLS ANC was found in May Shangrao economic development zone Jiangxi province the area is 30 acres We focus on R D production and sales of power batteries provide effective security solutions to c...

Страница 5: ...5...

Страница 6: ...object Do not try to open it with a hammer or step on it Do not strike throw or subject the battery to severe physical shock Do not directly solder the battery terminals Do not attempt to disassemble...

Страница 7: ...ance less than 10 K V 3 Ammeter Standard class specified in the national standard or more sensitive class Total external resistance including ammeter and wire is less than 0 01 4 Impedance Meter Imped...

Страница 8: ...itted fitting based on the steady decrease range 2000 2800 cycles capacity retention curve The cycling test is time consuming Therefore we predicted the cycling life based on the fitted curve The pred...

Страница 9: ...rcharge protection Overcharge detection voltage 3 65 0 025V Overcharge detection delay time Typical 1 0s Overcharge release voltage 3 38 0 02V Cell over discharge protection Over discharge detection v...

Страница 10: ...rge high T recover 60 5 Charge low T protection 5 5 Charge low T recover 0 5 Discharge low T protection 20 5 Discharge low T recover 15 5 Balance Balance threshold voltage 3 45V Communication It has R...

Страница 11: ...11 6 CASE STRUCTURE...

Страница 12: ...12 7 PACKAGING...

Страница 13: ...d Lianding Testing Building No 18 Center Road of Yayuan Industrial Zone Nancheng District Dongguan Guangdong China Certificate No PNS2009083 6 01001 Th e following prod uct has bee n tested by us w th...

Страница 14: ...ditions Factory Warranty apply exclusively to Sunsynk Ltd s products of the following types Covered Products SSCLK3 1 SSCLK5 6 Valid Date from which were manufactured by and bear the original manufact...

Страница 15: ...rtion of the Warranty Period or 90 days from the date of the repair or replacement whichever is greater c This Factory Warranty covers Sunsynk Ltd costs for materials necessary to re establish trouble...

Страница 16: ...es incurred by Sunsynk Ltd as a result of Sunsynk Ltd s attempt to repair replace or re perform i Sunsynk Ltd is not liable for product s damaged through installer error or installation error regardle...

Страница 17: ...ered by this Factory Warranty you must submit the claim in writing Claim Notice to Sunsynk Ltd within the applicable Warranty Period to Sunsynk Ltd s address set forth above or such future address as...

Страница 18: ...ranty In no event will Sunsynk Ltd be held responsible or liable for any personal injuries resulting from the use of the system or for any other damages whether direct indirect incidental or consequen...

Страница 19: ...ing 171 Wai Yip Street Kwun Tong Kowloon Hong Kong Tel HK 852 2884 4318 Fax 852 2884 4816 Tel UK 44 151 528 9945 Tel SA 27 1108 39837 sales globaltech china com Audio Training manuals on Apple Pod Cas...

Отзывы: