18
COMPARATOR SCREEN
This screen is used when monitoring is enabled on the “Pulse Settings” Screen. However users
have the capability to turn the function on or off.
•
Desired (voltage, current, or power)
- This displays the desired (voltage, current, or
power) that has been selected on the “Pulse Settings” screen.
•
Monitored (voltage, current, or power)
- This displays the actual (voltage, current, or
power) that was achieved on the previous weld. The number will be 0 if the comparator was
turned off on the previous weld.
•
Maximum and Minimum (voltage, current, or power) -
The user can select the max and
min (voltage, current, or power) that is allowable through the weld.
•
If out of range
- If weld (voltage, current, or power) goes outside the range set in the min
and max, there are 3 options for the user to decide what happens next: