68
• Questions? Call or Text +1-801-658-0015
SUNSTONE CDDP-A USERS GUIDE
Index Input Register
Length Notes
74
Waveform Report Starting Voltage
1
mV
75
Waveform Report P1 Start Time
1
76
Waveform Report P1 End Time
1
77
Waveform Report P2 Start Time
1
78
Waveform Report P2 End Time
1
79
Waveform Report Total Duration
1
80
Waveform Report P1 Duration
1
81
Waveform Report P2 Duration
1
COMPARATOR RESULTS
Comparator Result (hex) Name
0x0000 Weld Good
0x0001 Weld Bad
0x0002 Weld Bad - E-Stop
0x0003 Part Check Failed
FILE RECORDS
File Number File Record
Length
0x0001 Previous Weld Record Time (1 Count = 0.05 ms)
0x01F4
0x0002 Previous Weld Record Voltage (mV)
0x01F4
0x0003 Previous Weld Record Current (A)
0x01F4
0x0004 Previous Weld Record Power (daW)
0x01F4
File Records are an array of data that consists of the raw weld waveform data of the previous weld. File Records
can each have up to 0x01F4 (500) data values. An example of the data table follows:
FILE RECORDS: RAW DATA (EXAMPLE)
Time (ms)
Voltage (V)
Current (A)
Power (W)
0.45
0
0
0
0.6
0.731
0
0
0.7
7.012
99
690
0.85
7.462
643
4790
0.95
7.368
1208
8900
…
…
…
…