SUNSTAR RESIDENTIAL INSTALLATION MANUAL
35
AUTOMATIC CONTROL SYSTEMS
IF USING AN AUTOMATIC CONTROL SYSTEM TO CONTROL THE SOLAR
POOL HEATING SYSTEM, FOLLOW THESE ADDITIONAL STEPS:
1.
Follow all instructions outlined in the installation
manual of the automatic control system being used.
2.
Install the actuator motor onto the three-way diverter valve
and wire it to the controller per manufacturer instructions.
3.
Install the roof temperature sensor on the roof adjacent to the solar collectors.
The sensor should be attached to the roof (not the solar collectors or piping)
using a roofing screw and sealant. The sensor element needs to be in contact
with the roof surface to read an accurate temperature.
4.
Use approved sensor wiring and connect the roof temperature
sensor to the controller per manufacturer instructions.
5.
Install a pool water sensor into the pool filtration piping. The sensor should be
installed in a location that allows it to read the true temperature of the water
from the pool. The sensor probe should be in contact with the water in the pipe.
6.
Use approved sensor wiring and connect the water temperature
sensor to the controller per manufacturer instructions.
7.
Follow controller manufacturer instructions to complete
the installation and wiring of the controller.