9.2) Infusion of Pressured Air and Adjustment of Pneumatic Pressure
For safety, work with the power cut off.
Caution
9.2.1) Connection for Pressured Air
1) Connect air hose to quick joint socket.
2) Contract quick joint socket and quick joint plug .
3) Open finger valve and flow air in. Then, adjust the
air pressure to 0.39~0.44 MPa(4~4.5kgf/cm
2
).
[Note]
When the finger valve is closed after use, the
remaining air is rejected and the pressure is adjusted
to 0 MPa(0kgf/cm
2
).
Finger Valve
Air Hose
Plug
Quick Joint Socket
When the air pressure goes down (under 3kgf/cm
2
), an error is indicated and the machine operation is
stopped.
Caution
9.2.2) How to Adjust the Air Pressure
-
Pull the adjustment handle on the upper part of
the filter controller, which is attached to the back
of the table, up as shown in the picture. When the
handle is turned clockwise the pressure goes up
and goes down when the handle is turned in the
opposite direction. Adjust to the appropriate
pressure 0.39~0.44MPa (4~4.5kgf/cm
2
) indicated
in the pressure gauge, then press and fix the
adjustment handle into its place.
9.3) Attaching the Pressure Plate Sheet
and Adjusting the Height of the Slider
Base
9.3.1) How to attach the pressure plate sheet
-
Attach the pressure plate sheet where the slider
base and the pressure plate meet as shown in the
picture.
Direction of Face Plate
Presser
Plate
Presser Plate Sheet
2mm
2mm
17.8mm
Содержание SPS/E-1306 Series
Страница 2: ......
Страница 18: ...18 4 5 4 Food pedal switch connection Connect a plug of pedal switch with control box Pedal Switch ...
Страница 49: ...49 9 6 Air System Ciruit Diagrams 9 6 1 SPS E 1306 1507 HS 20 ...
Страница 50: ...50 9 6 2 SPS E 1306 1507 HS 21 ...
Страница 51: ...51 9 6 3 SPS E 1306 1507 HS 22 ...
Страница 52: ...52 9 6 4 SPS E 1306 1507 HS 22 1 ...
Страница 53: ...53 1 10 0 DRAWING OF TABLE 10 1 SPS E 1306 1507 Series ...