-8-
If you need to replace the burner assembly, loosen screws A and
B, unscrew the tubing fittings C, and disconnect the assembly,
see Figure 5
.
WARNING:
FAILURE TO KEEP THE PRIMARY AIR
OPENING(S) OF THE BURNER(S) CLEAN MAY RESULT IN SOOTING
AND PROPERTY DAMAGE.
WARNING:
:DO NOT ALLOW FANS TO BLOW DIRECTLY INTO
THE FIREPLACE. AVOID DRAFTS THAT ALTER BURNER FLAME
PATTERNS.
OXYGEN DEPLETION SENSOR (ODS) SERVICING
Dust and dirt may effect heater performance.
This heater draws air into the bottom of it during normal
operation. In the process, dust and dirt will also be drawn
into the heater. The frequency of cleaning will depend on
how and where the heater is used. At a minimum, you
should clean the heater at least once a year, at the
beginning of the heating season.
If your pilot will not stay lit, try cleaning it. Use a can of
compressed air, such as is used to clean a computer, to
blow dust out of the pilot assembly. Sometimes just
blowing air back through the pilot will get rid of the dirt.
If that fails to solve the problem, remove the wire clip that
holds the metal strip onto the pilot assembly. Remove the
cover and blow any dust out. Reassemble and check for
proper operation.
If that fails, the pilot assembly should be removed and air
blown through the assembly and gas line as shown in
Figure 6. To prevent damage to this assembly, follow the
instructions below for disassembly and assembly of the
ODS for cleaning.
WARNING:
Never use needles, wires,
or similar cylindrical objects to clean the pilot orifice. This
will only damage the calibrated ruby orifice (about the size
of the head of a pin) which controls the pilot gas flow.
Grab Nut A with an open-end wrench and loosen Nut B
from the pilot tubing. Blow air pressure through the holes
as indicated in Figure 6. This should blow out any foreign
materials. To reassemble, tighten Nut B by grabbing Nut A
with the open-end wrench.
NOTE:
When the heater is
reassembled, always check for gas leaks as outlined in the
Gas Supply section of these instructions.
WARNING:
DO NOT USE A BLOWER INSERT,
HEAT EXCHANGER INSERT OR OTHER
ACCESSORY NOT APPROVED FOR USE WITH
THIS HEATER.
WARNING: This vent-free heater is approved for use only with the type of gas indicated on the heater nameplate.
Field conversion is not permitted. Contact our Technical Service Department at (704) 372-3486 if you have any
problems.