35
8-6. Adjusting clearance between upper side of hook stopper and needle plate groove
As in Figure 53, the clearance between the upper side of hook stopper and needle plate groove is set to 1~1.2mm by default. This
clearance could impact the stitch tension and thread separation when trimming, so it needs to be checked. If there is a problem with
the clearance, move the hook tray bushing
①
up and down to adjust as in Figure 53, but move it cautiously after checking the
assembly status of surrounding parts. The hook tray bushing
①
is fixed with a fixing screw
②
and when moving it vertically,
adjust with the hook tray bushing fixing screw
②
, hook shaft gear fixing screw
③
, the bushing adjusting pin fixing screw
④
and
the bushing adjusting pin
⑤
. After completion, the hook shaft should turn smoothly without moving vertically. Fix the lower shaft
gear while the hook edge and the needle timing do not change.
8-7. Adjusting clearance between hook and opener
When the opener
②
is pulled into the arrow direction to the max, the clearance between hook
①
and opener
②
should be
0.1~0.3mm. Loosen the opener position stopper clamp screw
③
and turn it left and right to adjust that.
[ Figure 53 ]
[ Figure 54 ]
③
Содержание KM-1957-7
Страница 2: ......