background image

Quickie

®

 Q200

®

 R General Manual

253470 Rev. B

5

2.0 SAFETY

Follow the instructions carefully next to these warning symbols! Not paying careful attention to these 
instructions could result in physical injury or damage to the wheelchair or the environment. Wherever
possible, safety information is provided in the relevant chapter.

2.1 Symbols and labels used on the product

The signs, symbols, and instructions affi

  xed to the wheelchair comprise part of the safety facilities. They 

must never be covered or removed. They must remain present and clearly legible throughout the entire 
lifespan of the wheelchair.

Replace or repair all illegible or damaged signs, symbols, and instructions immediately. Please contact your 
Sunrise Medical authorized dealer for assistance.

Fig. 2.1:  

Chair serial number: located on right side of the base on the bottom front of the battery box.

Fig. 2.2:  

Transit fi xation point.

Fig. 2.3:  

Warning – Danger of fi nger entrapment (pinch point).

Fig. 2.4:  

Warning – Maximum user weight for the wheelchair.

Fig. 2.5:  

Location of Motor Serial Number Label.

Fig. 2.6:  

Warning – Hot Label on Motor.

2.2 Safety: Temperature

WARNING!

1. 

Avoid physical contact with the wheelchair’s motors at all times. Motors are continuously in motion 
during use and can reach high temperatures. After use, the motors will cool down slowly. Physical 
contact could cause burns. Allow the motors after using at least 30 minutes to cool down.

2. 

If you do not use the wheelchair, ensure that it is not exposed to direct sunlight for lengthy periods of 
time. Certain parts of the wheelchair, such as the seat, the back, and the armrests can become hot if 
they have been exposed to full sunlight for too long. This may cause burns or allergic reactions to the 
skin.

2.3 Safety: Moving parts

DANGER!

A wheelchair has moving and rotating parts. Contact with moving parts may result in serious physical injury 
or damage to the wheelchair. Contact with the moving parts of the wheelchair should be avoided (Fig. 2.7).
• 

Wheels (turning and caster)

• 

Powered tilt in space adjustment

• 

Swing-away bracket of the controller

• 

Power elevating leg rests

2.4 Safety: Electromagnetic radiation

CAUTION!

The standard version of your electric wheelchair has been tested on the applicable requirements with 
respect to electromagnetic radiation (EMC requirements). In spite of these tests:

It cannot be excluded that electromagnetic radiation may have an infl uence on the wheelchair. For example:
• Mobile 

telephones

• 

Large-scale medical apparatus

• 

Other sources of electromagnetic radiation

It cannot be excluded that the wheelchair may interfere with electromagnetic fi elds. For example:
• Shop 

doors

• 

Burglar alarm systems in shops

• 

Garage door openers

In the unlikely event that such problems do occur, we request that you notify your Sunrise Medical 
authorized dealer immediately.

DANGER!

1. 

When operating two-way radio, walkie-talkies, C.B. radio, Amateur radio, public mobile radio, and 
other powerful transmitting devices the wheelchair should be brought to a halt and turned off .

2. 

The operation of cordless, mobile telephones, and cell phones including hands-free devices is 
permitted, but if abnormal operation of the wheelchair is encountered then the chair must be brought 
immediately to a halt and turned off .

 

Controller: Refers to the user manual for the controller.

Fig. 2.3

Fig. 2.4

Fig. 2.2

Fig. 2.7

Fig. 2.6

Fig. 2.5

Fig. 2.1

Содержание Quickie Q200 R

Страница 1: ...Medical com Ingrese a la p gina del producto espec fi co para descargar el manual o comun quese con el proveedor autorizado de Sunrise Medical Au Fournisseur Ce manuel doit tre remis l utilisateur de...

Страница 2: ...ealer ______________________________________________________ Address _____________________________________________________ Telephone __________________________________________________ Serial _________...

Страница 3: ...4 6 Check after setup and or adjustment of wheelchair 9 5 0 USING THE WHEELCHAIR 10 5 1 Checking wheelchair before use 10 5 2 Making a transfer 10 5 3 Driving the wheelchair 10 5 4 Curves 11 5 5 Brea...

Страница 4: ...seating system The user manual for the controller The user manual for the battery charger When necessary this general user manual refers to other manuals as shown below Seating system Refers to the u...

Страница 5: ...e back and the armrests can become hot if they have been exposed to full sunlight for too long This may cause burns or allergic reactions to the skin 2 3 Safety Moving parts DANGER A wheelchair has mo...

Страница 6: ...Vent tray DANGER Using a vent tray will affect the stability and overall weight of your wheelchair 1 Ensure that the batteries and the ventilator are securely fastened to the tray before use 2 Familia...

Страница 7: ...it includes both the user and any weight of accessories fitted to the wheelchair is marked on the serial number label which is affixed to the chair The overall maximum user weight shall not exceed Sta...

Страница 8: ...r and or damaged or broken some of the components Wheelchairs involved in sudden stops should be inspected for possible failures in frame and or components Frame damage may be represented by but not l...

Страница 9: ...Adjusting the center of gravity on a powered wheelchair is both physically demanding and safety critical Sunrise Medical strongly recommends that this adjustment is only performed by a Sunrise Medica...

Страница 10: ...he normal capacity At temperatures below 23 F 5 C this will be roughly 50 This will reduce your range of action 5 2 Making a transfer Sunrise Medical recommends that you consult your health care provi...

Страница 11: ...adients in standard configuration 7 5 13 DANGER 1 Elevating tilting and leg rest adjustments can affect the wheelchair center of gravity Under certain conditions this might cause instability that coul...

Страница 12: ...s far as possible keep the joystick in the straight forward position The maximum obstacle or curb climbing height is 2 3 in 60 mm for Group 3 The approach speed and process can vary depending on your...

Страница 13: ...heelchair is in push 3 Never set the switch to the push position on a slope When the freewheel switch is set to push the automatic parking brake is deactivated This makes it possible for the wheelchai...

Страница 14: ...5 Do not attempt to operate any power seating option while this seating system is in motion 6 Do not attempt to operate the tilt power seating options around children 7 Through programming it is poss...

Страница 15: ...ld a charge 4 The battery terminals need to be checked regularly for signs of corrosion If any corrosion is apparent clean the terminals completely and apply petroleum jelly or silicone grease to the...

Страница 16: ...r place the charger directly above the battery being charged gases from the battery will corrode and damage the charger 6 Never charge a frozen battery A fully charged battery will rarely freeze but t...

Страница 17: ...the battery shroud To disconnect the batteries 1 Remove the front battery cover by lifting upwards on the handle at the front of the cover Fig 6 2 2 Undo the two GREY plugs that connect the two batte...

Страница 18: ...access and maneuverability to a forward facing position Securing the wheelchair with a strap restraint system This wheelchair has been successfully crash tested in accordance to ISO 7176 19 2008 using...

Страница 19: ...cupant Restraint Systems For Use in MotorVehicles Do not use WTORS designed to rely on the wheelchair structure to transfer occupant restraint loads to the vehicle 12 The wheelchair has been dynamical...

Страница 20: ...packed and labeled so they do not get lost during loading and unloading 4 The wheelchair may be transported by road rail sea or air and the batteries conform to IATA regulations 5 Before you travel pl...

Страница 21: ...locking nuts or nuts studs secured with a thread locking solution ensure that a suitable thread locking solution is reapplied to the fastener Daily checks Perform the daily check routine before drivi...

Страница 22: ...eplacing self locking nuts or nuts studs secured with a thread locking solution ensure that a suitable thread locking solution is reapplied to the fastener 6 Check all Velcro fastening straps for corr...

Страница 23: ...unctions properly it is essential that the tires are kept at the correct pressure The correct tire pressure is indicated on the side of the tire Tires that are too soft will have a negative effect on...

Страница 24: ...ng re used Prior to the wheelchair being re used it must be carefully prepared All surfaces which come into contact with the user must be treated with a disinfection spray To do this you must use a su...

Страница 25: ...chair off and then back on again 3 Check whether the battery plugs are all securely in place 4 Check whether the freewheel switch is in the DRIVE position 5 Check the position of the speed regulator 6...

Страница 26: ...4 2014 Class B Electrically powered wheelchairs scooters and their chargers Requirements and test methods 300 lbs 136 kg ISO 7176 8 2014 Requirements and test methods for impact static and fatigue str...

Страница 27: ...turn or repair of covered parts Contact Customer Service for a Returned Material Authorization RMA number and information as to where to return the product Upon contacting Customer Service please prov...

Страница 28: ...Customer Service 800 333 4000 In Canada 800 263 3390 Sunrise Medical 2842 Business Park Ave Fresno CA 93727 USA 2021 Sunrise Medical US LLC 10 2021 P N 253470 Rev B www SunriseMedical com...

Отзывы: