background image

Owner’s Manual

Содержание Quickie F40

Страница 1: ...Owner s manual...

Страница 2: ...Issue 6...

Страница 3: ...rds which we adhere to and details about the guarantee There are a wide range of accessories and adjustments available on the Quickie F40 For further information about these you should contact your wh...

Страница 4: ...r use page 7 10 Seating page 11 12 Using your wheelchair page 13 18 Penny and Giles Pilot Plus control pod page 19 VR2 page 20 21 Parallel Swing Away page 22 23 Batteries and charging page 24 33 User...

Страница 5: ...e agent If you do not know of an approved dealer in your area or have any other questions please write or telephone SUNRISE MEDICAL LIMITED HIGH STREET WOLLASTON WEST MIDLANDS DY8 4PS England Telephon...

Страница 6: ...s apply to all wheelchair parts for models purchased at full retail price 8 Under normal circumstances no responsibility will be accepted where the Wheelchair has required repair or replacement as a d...

Страница 7: ...cal and visual ability to control the vehicle safely If you are in any doubt as to the suitability of the powerchair contact your local Sunrise approved dealer for clarification prior to commencing us...

Страница 8: ...s in life a little care and attention goes a long way and your chair is no exception The recommended service interval is one year See service history on later page Emergency freewheel Please remember...

Страница 9: ...and water Take care to keep batteries upright at all times especially when transporting your wheelchair Note Before using your vehicle for the very first time please charge the batteries for a period...

Страница 10: ...her tilt seat or recline back then in certain circumstances your wheelchair could become unstable Before attempting to climb or descend a slope we strongly recommend that you return the seat and back...

Страница 11: ...just the height of the armrest pull back the lever of locking pin B and hold Lift or lower armrest to the required position and release pin to lock position Check armrest has seated properly Fig 1 Loc...

Страница 12: ...he pod For adjustment loosen the lowest stud using a 4 0 mm Allen key slide the arm to the required position and tighten the stud Fig 3 If a 90 degree or parallel swing away is fitted the control pod...

Страница 13: ...red height Re tighten the screw to secure position Fig 6 Locating tube Frame receiver Composite footrest Infinitely adjustable hanger Extension tube Socket key Adjustment collar 2 1 3 Footplate angle...

Страница 14: ...wards and ensure that the spring loaded pegs lock out on clearing the upright post Angle adjustable backrest If your powerchair has been fitted with the optional adjustable angle backrest Fig 8 it can...

Страница 15: ...cro Check sling for tension fig 9 fig 10 Detach the Velcro Loosen all the screws Seat cushion Velcro strips Seat cushions Seat cushions supplied by Sunrise Medical will have Velcro strips that corresp...

Страница 16: ...decrease the power automatically This operates in extreme conditions repetitive steep hill climbing in high ambient temperatures Contact your Sunrise Medical dealer if faults re occur fig 12 Power le...

Страница 17: ...only in an emergency or if your wheelchair needs to be moved manually To engage drive rotate the levers on the rear of the gearboxes towards drive wheels Engage drive before parking your powerchair Fi...

Страница 18: ...n the same way that a car driver always turns the steering wheel in the direction he wants to go even though the car and wheel may want to go another way Look ahead when you are driving and not at the...

Страница 19: ...ow the tension in the spring to locate the kerb climber into the right hand location bracket 5 Release the locking lever and ensure the locking pin is correctly positioned in the locating hole Fig 18...

Страница 20: ...speed so that the drive wheels climb the kerb smoothly and without hesitation As far as possible keep the joystick in the straight forward position Using your wheelchair Front transfers If you find t...

Страница 21: ...member that the last thing a car or lorry driver expects to see is a wheelchair backing off the kerb into the road If in any doubt do not risk crossing the road until you are certain that it is safe 2...

Страница 22: ...ff button Immobiliser plug Charger programmer socket To activate the immobiliser 1 Switch the chair on via the On Off button Fig 23 2 Insert the immobiliser plug into the charger programmer socket loc...

Страница 23: ...ns lit this means that everything is OK It flashes to indicate any fault that may have arisen Slow and stable flashing means the batteries need charging If it flashes once every 2 5 seconds this means...

Страница 24: ...used by more than one person to ensure there is no cross infection Control system to be switched off prior to cleaning Programming port Hand Control The programming port is placed in the bottom front...

Страница 25: ...ramme the controller you need a special programming device Handheld or PC software which is available through your Sunrise Medical Dealer Note SUNRISE MEDICAL does not accept responsibility for damage...

Страница 26: ...the wheelchair in the normal manner Caution Do not hang any items on or over the parallel swing away remote assembly as this could damage the swing away Ensure that you set the speed of the attendent...

Страница 27: ...with your control of the chair It is important that the joystick boot is replaced if it is torn or brittle failing to do so could cause substance damage to the controller and unexpected movement of t...

Страница 28: ...se the retaining hooks Lift the basket to clear the retaining hooks and pull it out so that the battery box can be removed Disconnect the power plug from the control box panel and remove the battery b...

Страница 29: ...the hooks this enables the basket to slide out sufficiently to allow the removal of the battery boxes Disconnect the power plug from the control box and the tandem connectors The battery boxes can no...

Страница 30: ...essed in amps per hour e g 30amp hr The higher the number the bigger the battery size weight and potentially the greater the distance you can travel Sunrise Medical only fit as standard maintenance fr...

Страница 31: ...teries and can lead to shortened distances and premature failure 7 Do not top up the charge of your batteries during the day Wait until the evening for a full overnight charge 8 As a general rule main...

Страница 32: ...arger has been specified for use in Continental Europe it will contain a European two pin plug which does not have a fuse In this case the fuse is located in the fascia panel of the charger Safety fea...

Страница 33: ...er approximately 30 minutes If the lamp continues to blink consult Sunrise Medical or your local Sunrise Medical dealer 24V 8A charger indicator lights The charger has 3 light indicators each clearly...

Страница 34: ...ber charging light will start to flash as charging commences When the amber light is steady charging is complete If not needed for immediate use the charger can remain connected switched on for extend...

Страница 35: ...rs should only be carried out by Sunrise Medical 8 The charger is designed for mains input voltages of 220V AC to 240V AC for chargers to operate with 110V AC in countries such as USA or North America...

Страница 36: ...f battery or charger Be extra cautious to reduce the risk of dropping a metal tool on to the battery It could spark or short circuit the battery or other electrical parts that may cause an explosion A...

Страница 37: ...nge figures stated should be seen as a theoretical maximum and could be reduced if any single or combination of the following circumstances occur 1 User weight heavier than 75kg 2 Batteries whose age...

Страница 38: ...ou may experience a reduction in the grip and traction of your wheelchair We recommend you take extra precautions in these conditions particularly on hills and slopes your wheelchair could become unst...

Страница 39: ...nd from the chair Sunrise Medical recommend that you consult your healthcare professional for assistance in developing your personal front or side transfer technique to best suit your needs and avoid...

Страница 40: ...mal level of ground speed In fact it is safer to proceed slowly down steep descents and stop immediately if any anxiety arises regarding directional control If the chair picks up speed centre the cont...

Страница 41: ...Point Webbing Restraint as per the diagram shown Fig 48 Fig 48 Transportation in vehicles Users should not sit in the wheelchair while riding in any and all means of transportation Only permanently i...

Страница 42: ...specting electrical connections pay attention to the battery connections the connection of batteries to power loom and plug in sockets for the joystick control box and lights and indicators Tyre wear...

Страница 43: ...e dates Upholstery Seat Back Armpads Electrics Condition of loom Connections Lights where fitted Test run Forwards Reverse Emergency stop Left turn Right turn Up down slope Over obstacles Parking brak...

Страница 44: ...SAFETY MUST BE OBSERVED Ensure all electrical connections are made and firm Wipe vehicle with a damp cloth Check tyre pressures Ensure lights and indicators are operational and clean Check tyres for...

Страница 45: ...inely caring for our customers We pride ourselves not only on designing and building the most innovative products but also on our commitment to offer an excellent standard of customer service both dur...

Страница 46: ...Issue 6 42...

Страница 47: ...43 Issue 6...

Страница 48: ...Sunrise Medical Limited High Street Wollaston West Midlands DY84PS England Tel 01 384 44 66 88 Fax 01384 44 66 99 www sunrisemedical co uk...

Отзывы: