97

LT-1928

I N F O R M A C I Ó N   D E   Ó R D E N E S   Y   L I S T A D O   D E   P A R T E S

Componentes (continuación)

515AKS

515ADS

515ADZ

515AKZ

Accesorios

“T” de Tanque de Acumulación

444-582

444-582

444-582

444-582

Medidores de Flujo

Medidor de Flujo Estándar

505DZ-607

505DZ-607

505DZ-607

505DZ-607

Medidor de Salida Baja

515LF-607

515LF-607

515LF-607

515LF-607

Perilla de Medidor de Flujo

PVO2D-618

PVO2D-618

PVO2D-618

PVO2D-618

Equipo de Espuma

515ADZ-600

515ADZ-600

515ADZ-600

515ADZ-600

Fusible (Para Placa PC)

515AKZ-610

515ADZ-627

515ADZ-627

515AKZ-610

Mangueras

1/8” DI (Azul) (4’ Lg)

444-554

444-554

444-554

444-554

1/4 DI (Azul) (4’ Lg)

444-525

444-525

444-525

444-525

1/2 DI (Trenzada) (4’ Lg)

444-549

444-549

444-549

444-549

1/2 DI (Trenzada) (Formada)

515ADZ-649

515ADZ-649

515ADZ-649

515ADZ-649

1/2 DI (Silicona) (2’ Lg)

505DZ-634

505DZ-634

505DZ-634

505DZ-634

Abrazaderas de Manguera

Plástica (Manguera de 1/4” DI)

444-524

444-524

444-524

444-524

Plástica (Mangueras 1/2” DI)

444-538

444-538

444-538

444-538

Abrazadera Escalonada (Mangueras 1/2” DI)

444-566

444-566

444-566

444-566

Medidor de Tiempo

PV5LD-617

PV5LD-617

PV5LD-617

PV5LD-617

Panel de Luces

303DS-615

303DS-615

505DZ-615

505DZ-615

Monturas de Motor

505IZ-609

505IZ-609

505IZ-609

505IZ-609

Tuerca (Montaje de Compresor)

303DZ-630

303DZ-630

303DZ-630

303DZ-630

Puerto de Salida de Oxígeno

303DZ-606

303DZ-606

303DZ-606

303DZ-606

Placa PC

515AKS-622

515ADS-622

515ADZ-622

515AKZ-622

Cordón Eléctrico

PV5LD-618

PV5LD-618

PV5LD-618

PV5LD-618

Correa de Cordón Eléctrico

MC29D-657

MC29D-657

MC29D-657

MC29D-657

Pasacables de Cordón Eléctrico

505DZ-645

505DZ-645

505DZ-645

505DZ-645

Interruptor de Encendido

505DZ-508

505DZ-508

505DZ-508

505DZ-508

Regulador de Presión

MC29D-612

MC29D-612

MC29D-612

MC29D-612

Tornillos

Gabinete

303DZ-628

303DZ-628

303DZ-628

303DZ-628

Tamiz

515A-621

515DZ-619

515DZ-619

515A-621

Válvula Rotativa

515ADZ-702

515ADZ-702

515ADZ-702

515ADZ-702

Manguera de Válvula (Trenzada / Formada)

515ADZ-649

515ADZ-649

515ADZ-649

515ADZ-649

Arnés de Cableado

Arnés de Comunicación

515DS-608

515DS-608

515DS-608

515DS-608

Arnés Principal

515AKS-623

515DZ-623

515DZ-623

515AKS-623

Arnés de Válvula

515ADZ-621

515ADZ-621

515ADZ-621

515ADZ-621

Herramientas

Ensamble de Prueba de Presión

303DZ-637

Medidor de Presión / Vacío

PVO2D-601

Equipo de Servicio

444-501

Содержание DeVilbiss 515ADS

Страница 1: ...r Service Manual DeVilbiss Concentrador de Ox geno Serie de 5 Litros Manual de Servicio CAUTION Federal U S A law restricts this device to sale by or on the order of a physician PRECAUCI N Las leyes F...

Страница 2: ...Troubleshooting Chart C 12 Troubleshooting Chart D 12 Troubleshooting Chart E 12 Troubleshooting Chart F 13 COMPONENT TESTING REPAIR AND REPLACEMENT Proper Repair Procedures 14 Cabinet Removal 14 Accu...

Страница 3: ...entrated oxygen for therapeutic applications Room air is a mixture of 78 nitrogen 21 oxygen 1 argon and other gases The concentrator draws in room air separates the nitrogen from the oxygen and delive...

Страница 4: ...o an electrical out let controlled by a wall switch the outlet should be indepen dent of other appliances E Do not use an electrical adapter or extension cord with the oxygen concentrator F Only opera...

Страница 5: ...aked flames Do not use in rooms heated by paraffin or portable gas heaters WARNING Electric Shock Hazard Only qualified Sunrise Medical homecare providers may remove the cabinet 4 Attach the appropria...

Страница 6: ...f the oxygen purity continues to fall to a low enough level the yellow Low Oxygen light will turn off and the red Service Required light will turn on NOTE Refer to Specifications for specific alarm se...

Страница 7: ...ure relief valve located on the compressor head ROUTINE PATIENT MAINTENANCE The oxygen patient should perform the following maintenance Oxygen Humidifier reusable bottles only The patient should clean...

Страница 8: ...plug the unit remove the cabinet and loosen the bib b Remove the hose from each end of the filter Figure 8 and discard the filter c Install the new final bacteria filter with the IN fitting toward the...

Страница 9: ...ft and alternately pressurize the sieve beds The PC board also activates the electronic alarm system A high pressure condition will be indicated with a popping type sound produced by release of pressu...

Страница 10: ...tart when the unit is turned on 1 Verify that the cooling fan is running if it is not determine where you are losing power 2 Check for compressor voltage at the compressor connector 3 If voltage is pr...

Страница 11: ...check valve Pressure regulator not adjusted Adjust or replace pressure regulator properly or defective Little or no oxygen flow Flow meter not adjusted properly Adjust flow meter Hose disconnected to...

Страница 12: ...ll hoses and fittings Defective compressor Replace compressor T R O U B L E S H O O T I N G TROUBLESHOOTING CHART B Visible Alarm Audible Alarm Compressor Power Light Blinking Pulsing OFF OFF Other Sy...

Страница 13: ...m refer to low oxygen concentration symptom in Troubleshooting Chart A Both OSD lights are illuminated Defective OSD Replace PC board Yellow Low Oxygen light Oxygen level is low Check concentration wi...

Страница 14: ...ust be applied to the male threads omitting the first thread to eliminate the possibility of tape particles entering the oxygen sys tem LOX 8 sealant may be used in place ofTeflon tape WARNING Electri...

Страница 15: ...UTION The 515AKS and 515AKZ concentrators use a GSE compressor with a 10 mfd capacitor If replacement is necessary be sure the correct capaci tor is installed WARNING Electric Shock Hazard When replac...

Страница 16: ...ubing from the compressor intake port fitting CAUTION If the unit has been running recently the compressor may be hot To inspect and or replace internal components Figures 11A 12A 1 Remove the eight s...

Страница 17: ...d between the final bacteria filter and the oxygen outlet fitting This check valve allows oxygen to flow only out of the unit When the unit is turned off and oxy gen flow stops the check valve closes...

Страница 18: ...internal structure of the unit 4 Remove the tubing from the fittings at the top of each sieve bed 5 Remove the hose clamps and hose from the bottom of the sieve beds 6 Install new sieve beds in rever...

Страница 19: ...place the bib and front and back cabinets ROTARY VALVE Figure 13 The timed rotary valve alternately distributes pressure sup plied by the compressor to the sieve beds While one bed is being pressurize...

Страница 20: ...the accumulator tank allows oxygen to pass through the sieve beds to the accumulator tank when the bed pressure is greater than the accumulator tank pressure These valves also prevent reverse flow of...

Страница 21: ...ont AKS AKZ 28 Figure 5B Front close up AKS AKZ 29 Figure 6 Lower front close up ADS ADZ 30 Figure 6A Lower front close up AKS AKZ 31 Figure 7 Upper front close up ADS ADZ 32 Figure 7A Upper front clo...

Страница 22: ...A N D V I E W S Light Panel Oxygen Outlet Port Bib Front Cover Caster Base Power Light green Flow Meter Knob OSD Indicator Lights OSD units only Service Required Light Red Power Switch Flow Meter Circ...

Страница 23: ...23 LT 1928 F I G U R E S D I A G R A M S A N D V I E W S Front cover Rear cover Cabinet screw Power Cord Strap Power Cord Exhaust Grill Caster Figure 2 Exterior Side View...

Страница 24: ...24 LT 1928 F I G U R E S D I A G R A M S A N D V I E W S Air Filter Communication Port with cover removed Figure 3 Exterior Rear View Cabinet Screws Filter Door Cabinet Screws...

Страница 25: ...Rear View 515ADS and 515ADZ Cooling Fan Mounting Plate Screw Pressure Exhaust Hose Silicone 1 2 ID Power Cord Strain Relief on 115 volt units Compressor Connector Accumulator Tank Ladder Clamp Intake...

Страница 26: ...26 LT 1928 F I G U R E S D I A G R A M S A N D V I E W S Figure 4A Interior Rear Lower View 515AKS and 515AKZ Compressor Connector IEC Connector for models 515AKS and 515AKZ...

Страница 27: ...1928 27 F I G U R E S D I A G R A M S A N D V I E W S Figure 5 Interior Front View 515ADS and 515ADZ Left Sieve Bed PC Board Rotary Directional Air Valve Sieve Bed Cable Ties Wire Harness Right Sieve...

Страница 28: ...M S A N D V I E W S Figure 5A Interior Front View 515AKS and 515AKZ NOTE Sieve beds shown are used only on models 515AKS and 515AKZ Left Sieve Bed PC Board Rotary Directional Air Valve Sieve Bed Cabl...

Страница 29: ...29 LT 1928 F I G U R E S D I A G R A M S A N D V I E W S Figure 5B Interior Front View Close Up 515AKS and 515AKZ Intake Silencer for models 515AKS and 515AKZ...

Страница 30: ...D V I E W S Figure 6 Interior Front Lower View 515ADS and 515ADZ Compressor Mounting Plate Hex Nut Bib Mounting Slot Rotary Directional Air Valve Right Sieve Bed Hose Left Sieve Bed Hose Rotary Valve...

Страница 31: ...ont Lower View 515AKS and 515AKZ NOTE Sieve beds shown are used only on models 515AKS and 515AKZ Compressor Mounting Plate Hex Nut Bib Mounting Slot Rotary Directional Air Valve Right Sieve Bed Hose L...

Страница 32: ...Wires Oxygen Outlet Tubing 1 8 ID Sieve Bed Test Point Oxygen Accumulator Tank Fuse OSD Flow MeterTubing shown disconnected for removal of Bib CAUTION Do NOT insert mounting screw in this hole Valve...

Страница 33: ...AKS and 515AKZ Sieve Bed Test Point Oxygen Outlet Tubing 1 8 ID Hour Meter Wires Oxygen Outlet Tubing 1 8 ID Sieve Bed Test Point Oxygen Accumulator Tank Fuse OSD Tubing to Flow Meter Valve Wire Harne...

Страница 34: ...Switch Final Bacteria Filter Circuit Breaker Final Check Valve Oxygen Outlet Port Screws Handle Bib Tab Light Panel Ribbon Connector Brown Wire or Double Black Wires Double Black Wires or Brown Wire...

Страница 35: ...r Top View 515ADS and 515ADZ Sieve Bed Test Point Communication Port Wire Harness Fixed Orifice Tubing to Flow Meter Sieve Bed Test Point Pressure Regulator Sieve Bed Check Valve 1 4 x 1 8 Tubing Redu...

Страница 36: ...shown are used only on models 515AKS and 515AKZ Sieve Bed Test Point Communication Port Wire Harness Fixed Orifice Tubing to Flow Meter Sieve Bed Test Point Pressure Regulator Sieve Bed Check Valve 1...

Страница 37: ...xhaust Hose Silicone 1 2 ID Figure 10 Interior Rear Lower View Exhaust Muffler Intake Filter Elbow Capacitor Power Cord Connector Compressor Connector Cooling Fan Ladder Clamp Valve Exhaust Hose 1 2 I...

Страница 38: ...8 LT 1928 F I G U R E S D I A G R A M S A N D V I E W S Figure 11 Compressor Thomas Nexus Pressure Relief Valve Exhaust Fitting Intake Fitting Motor Mount Compressor Mounting Plate Electrical Connecto...

Страница 39: ...s Compressor With Head Removed Retainer Reed Valve or Flapper Head Gasket Valve Plate top view Rod Screw Sleeve Cup Retainer Plate Rod Screw Cup Seal Reed Valve or Flapper Valve Screw O Ring Valve Pla...

Страница 40: ...40 LT 1928 F I G U R E S D I A G R A M S A N D V I E W S Figure 12 Compressor GSE Pressure Relief Valve Exhaust Fitting Intake Fitting Motor Mount Compressor Mounting Plate Electrical Connector...

Страница 41: ...oved Retainer Reed Valve or Flapper Compressor Head Valve Plate top view Compressor Electrical Connector Rod Screw Sleeve Cup Seal Rod Screw Cup Retainer Reed Valve or Flapper Screw O Ring Valve Plate...

Страница 42: ...G U R E S D I A G R A M S A N D V I E W S Figure 13 Rotary Valve Stepper Motor Valve Wire Harness Left Sieve Bed Fitting Right Sieve Bed Fitting Pressure Exhaust Fitting Pressure Intake Fitting Rear V...

Страница 43: ...43 LT 1928 F I G U R E S D I A G R A M S A N D V I E W S Figure 14 Pneumatic Diagram...

Страница 44: ...44 LT 1928 F I G U R E S D I A G R A M S A N D V I E W S Figure 15 Wiring Diagram 115 VOLT UNITS 230 VOLT UNITS...

Страница 45: ...der this warranty must be performed by a qualified Sunrise provider and or an Authorized Service Center Labor costs incurred by a qualified Sunrise provider are excluded and will not be reimbursed Onl...

Страница 46: ...AYS AFTER SHIPMENT OF THE NEW COMPONENTS IF THE COMPONENTS ARE NOT RECEIVED WITHIN THIS PERIOD AN INVOICE WILL BE ISSUED TO YOUR ACCOUNT REBUILT EXCHANGE PARTS PRICING IS AVAILABLE ONLY WITH THE RETUR...

Страница 47: ...Check Valves Bed Check Valve PVO2D 607 PVO2D 607 PVO2D 607 PVO2D 607 Final Check Valve PVO2D 607 PVO2D 607 PVO2D 607 PVO2D 607 Circuit Breaker 515KZ 615 515DZ 615 515DZ 615 515KZ 615 Cooling Fan 515UK...

Страница 48: ...44 566 Hour Meter PV5LD 617 PV5LD 617 PV5LD 617 PV5LD 617 Light Panel 303DS 615 303DS 615 505DZ 615 505DZ 615 Motor Mounts 505IZ 609 505IZ 609 505IZ 609 505IZ 609 Nut Compressor Mounting 303DZ 630 303...

Страница 49: ...und Level ISO 8359 1996 from front 48 0 dbA overall average Dimensions 27 75 H x 16 W x 14 D 70 5 x 40 6 x 35 6 cm Pressure Relief Valve 40 psig 5psig 276 kPa 34 5 kPa Operating System Time Cycle Pres...

Страница 50: ...C 60 Soluci n de Problemas Cuadro D 60 Soluci n de Problemas Cuadro E 60 Soluci n de Problemas Cuadro F 61 PRUEBA DE COMPONENTES REPARACI NY REEMPLAZO Procedimientos de Reparaci n Apropiados 62 Remoc...

Страница 51: ...nte concentrado para aplicaciones terap uticas El aire ambiental es una combinaci n de 78 de Nitr geno 21 de Ox geno 1 de Arg n y otros gases El concen trador absorbe el aire ambiental separa el nitr...

Страница 52: ...riente controlado por un interruptor de pared el tomacorriente deber a estar independiente de otros artefactos E No utilizar un adaptador el ctrico o cable de extensi n con el concentrador de ox geno...

Страница 53: ...s con calefacci n a base de parafina o calentadores port tiles de gas ADVERTENCIA Peligro de choque el ctrico S lo los proveedores calificados de Asistencia Domiciliaria de Sunrise Medical pueden reti...

Страница 54: ...ntin a decreciendo a un nivel lo suficiente mente bajo la luz amarilla de Low Oxygen Ox geno Bajo se apagar y la luz roja de Requiere Servicio se encender NOTA Ver Especificaciones para ajustes de ala...

Страница 55: ...squido desde una v lvula de liberaci n de presi n ubicada en el cabezal del com presor MANTENIMIENTO DE RUTINA DEL PACIENTE El paciente que utiliza ox geno deber realizar el siguiente mantenimiento Hu...

Страница 56: ...lojar el babero b Retirar la manguera a cada lado del filtro Figura 8 y descartar el filtro c Instalar el nuevo filtro final de bacterias con la indicaci n IN hacia el medidor de flujo d Ajustar el ba...

Страница 57: ...a ocasionando que cambie y presurice los tamices de manera alterna La Placa PC tambi n activa el sistema de alarma electr nico Una condici n de alta presi n se indicar con un sonido de chasquido produ...

Страница 58: ...io determinar por d nde se est perdiendo energ a 2 Verificar el voltaje del compresor en el conector del compresor 3 Si existe voltaje entonces el condensador o el compresor est n da ados 4 Si no exis...

Страница 59: ...or defectuoso Reemplazar V lvula de control defectuosa Reemplazar Regulador de presi n flojo o defectuoso Ajustar o reemplazar Flujo bajo o negativo Medidor de flujo no ajustado correctamente Ajustar...

Страница 60: ...les Ventilador y compresor fun cionando V lvula de alivio de presi n activada sonido de chasquido Fusible quemado en la Placa PC Reemplazar Placa PC defectuosa Reemplaza SOLUCI N DE PROBLEMAS CUADRO D...

Страница 61: ...baja concentraci n de ox geno en Soluci n de Problemas Cuadro A Ambas luces de OSD se encienden OSD defectuoso Reemplazar la Placa PC Luz amarilla de Bajo Ox geno se enciende El nivel de ox geno es b...

Страница 62: ...uevamente en servicio PRECAUCI N No aplicar la soluci n de detecci n de p rdidas a ninguna parte de la v lvula rotativa o el ensamblaje de la Placa PC ADVERTENCIA Al reparar el Concentrador de Ox geno...

Страница 63: ...a v lvula de alivio de presi n del com presor se abra NOTA Una v lvula rotativa que no funciona adecuadamente tambi n causar alta presi n en el tanque de acumulaci n y la activaci n de la v lvula de a...

Страница 64: ...e aire utilizando una soluci n de detecci n de p rdidas tal como Shoop o equivalente no debe con tener glicol etileno PRECAUCI N No aplicar soluci n de detecci n de p rdidas a ninguna parte de la v lv...

Страница 65: ...segurar la placa de montaje con dos tornillos en la parte posterior e instalar las tuercas en la parte anterior de la placa 6 Reconectar la manguera a la boca de salida del compresor 7 Reconectar el c...

Страница 66: ...y reconectar las mangueras MEDIDOR DE TIEMPO Para reemplazar el medidor de tiempo Figura 9 1 Verificar que la unidad est desenchufada del tomacorriente 2 Retirar los gabinetes anterior y posterior y...

Страница 67: ...lo del conector y luego reconectar el conector del cord n el ctrico 8 Recolocar el gabinete posterior y asegurar con los seis tornillos INTERRUPTOR DE ENCENDIDO Para reemplazar el interruptor de encen...

Страница 68: ...probar la v lvula rotativa Figuras 6 y 7 1 Retirar el gabinete anterior 2 Conectar los medidores de presi n a los puntos de prueba en la parte superior de los tamices para observar el ciclo de la uni...

Страница 69: ...eno desde el acumulador a los tamices Realizar la prueba de presi n del acumulador descrita en la secci n Prueba Reparaci n y Reemplazo de Componentes La misma explica los detalles sobre la colocaci n...

Страница 70: ...B Acercamiento Frontal AKS y AKZ 78 Figura 6 Acercamiento Inferior Frontal ADS y ADZ 79 Figura 6 A Acercamiento Inferior Frontal AKS y AKZ 80 Figura 7 Acercamiento Superior Frontal ADS y ADZ 81 Figur...

Страница 71: ...lida de Ox geno Babero Cubierta Frontal Rueda Base Luz de Encendido verde Perilla de Medidor de Flujo Luces Indicadoras de OSD en unidades con OSD solamente Luz de Servicio Requerido Rojo Interruptor...

Страница 72: ...928 F I G U R A S D I A G R A M A S Y V I S T A S Cubierta Frontal Cubierta Posterior Tornillo de Gabinete Correa del Cord n El ctrico Cord n El ctrico Rejilla de Escape Rueda Figura 2 Vista Lateral E...

Страница 73: ...LT 1928 F I G U R A S D I A G R A M A S Y V I S T A S Filtro de Aire Puerto de Comunicaci n sin la cubierta Figura 3 Vista Posterior Externa Tornillos de Gabinete Puerta de Filtro Tornillos de Gabine...

Страница 74: ...or de Enfriamiento Tornillo de Placa de Montaje Manguera de Escape de Presi n Silicona 1 2 pulg D I Cord n El ctrico y Pasacables en unidades de 115 voltios Conector de Compresor Tanque de Acumulaci n...

Страница 75: ...75 LT 1928 F I G U R A S D I A G R A M A S Y V I S T A S Figura 4 A Vista Inferior Posterior Interior 515AKS y 515AKZ Conector del Compresor Conector IEC para los Modelos 515AKS y 515AKZ...

Страница 76: ...G U R A S D I A G R A M A S Y V I S T A S Figura 5 Vista Frontal Interna 515ADS y 515ADZ Tamiz Izquierdo Placa PC V lvula de Aire Direccional Rotativa Ligaduras de Cables de Tamices Arn s de Cableado...

Страница 77: ...T A S Figure 5 A Interior Front View 515AKS and 515AKZ NOTA Los tamices mostrados s lo se usan en los modelos 515AKS y 515AKZ Tamiz Izquierdo Placa PC V lvula de Aire Direccional Rotativa Ligaduras de...

Страница 78: ...78 LT 1928 F I G U R A S D I A G R A M A S Y V I S T A S Figura 5 B Acercamiento Vista Frontal Interna 515AKS y 515AKZ Silenciador de Entrada para los Modelos 515AKS y 515AKZ...

Страница 79: ...tal Interna 515ADS y 515ADZ Tuerca Hexagonal de Placa de Montaje de Compresor Ranura de Montaje de Babero V lvula de Aire Direccional Rotativa Manguera de Tamiz Derecho Manguera de Tamiz Izquierdo Arn...

Страница 80: ...tamices mostrados s lo se usan en los modelos 515AKS y 515AKZ Tuerca Hexagonal de Placa de Montaje de Compresor Ranura de Montaje de Babero V lvula de Aire Direccional Rotativa Manguera de Tamiz Derec...

Страница 81: ...Cables de Medidor de Tiempo Tubo de Salida de Ox geno de 1 8 pulg D I Punto de Prueba de Tamiz Tanque de Acumulaci n de Ox geno Fusible OSD Tubo de Medidor de Flujo desconectado para retiro de Babero...

Страница 82: ...los 515AKS y 515AKZ Punto de Prueba de Tamiz Tubo de Salida de Ox geno de 1 8 pulg D I Cables de Medidor de Tiempo Tubo de Salida de Ox geno de 1 8 pulg D I Punto de Prueba de Tamiz Tanque de Acumulac...

Страница 83: ...ias Interruptor de Circuito V lvula de Control Final Tornillos de Puerto de Salida de Ox geno Manija Pesta a de Babero Cinta de Conexi n de Panel de Luces Cable Marr n o Cables Dobles Negros Cables Do...

Страница 84: ...o de Prueba de Tamiz Arn s de Cableado de Puerto de Comunicaci n Orificio Fijo Tubo al Medidor de Flujo Punto de Prueba de Tamiz Regulador de Presi n V lvula de Control de Tamiz Reductor de Tubos de 1...

Страница 85: ...15AKS y 515AKZ Punto de Prueba de Tamiz Arn s de Cableado de Puerto de Comunicaci n Orificio Fijo Tubo al Medidor de Flujo Punto de Prueba de Tamiz Regulador de Presi n V lvula de Control de Tamiz Red...

Страница 86: ...ra 10 Vista Inferior Posterior Interna Amortiguador de Escape Codo de Filtro de Entrada Conector de Cord n El ctrico Conector del Compresor Ventilador de Enfriamiento Abrazadera Escalonada Manguera de...

Страница 87: ...28 F I G U R A S D I A G R A M A S Y V I S T A S Figura 11 Compresor Thomas Nexus V lvula de Alivio de Presi n Boca de Escape Boca de Entrada Montura de Motor Placa de Montaje del Compresor Conector E...

Страница 88: ...de Boquilla o Aleta Junta Principal Placa de V lvula vista superior V stago Tornillo Manga Placa de Ret n de Taza Tornillo de V stago Junta Herm tica V lvula de Boquilla o Aleta Tornillo de V lvula A...

Страница 89: ...LT 1928 F I G U R A S D I A G R A M A S Y V I S T A S Figura 12 Compresor GSE V lvula de Alivio de Presi n Boca de Escape Boca de Entrada Montura de Motor Placa de Montaje de Compresor Conector El ctr...

Страница 90: ...Compresor Placa de V lvula vista superior Conector El ctrico de Compresor V stago Tornillo Manga Junta Herm tica Tornillo de V stago Ret n de Taza V lvula de Boquilla o Aleta Tornillo Anillo O Placa...

Страница 91: ...A G R A M A S Y V I S T A S Figura 13 V lvula Rotativa Motor Escalonado Arn s Cableado de V lvula Boca de Tamiz Izquierdo Boca de Tamiz Derecho Boca de Escape de Presi n Boca de Entrada de Presi n Vi...

Страница 92: ...92 LT 1928 F I G U R A S D I A G R A M A S Y V I S T A S Figure 14 Diagrama Neum tico...

Страница 93: ...93 LT 1928 F I G U R A S D I A G R A M A S Y V I S T A S Figura 15 Diagrama de Cableado...

Страница 94: ...la presente garant a deber ser realizado por cualquier proveedor califica do de Sunrise y o Centro de Servicio Autorizado Los costos de mano de obra incurridos por un proveedor calificado de Sunrise...

Страница 95: ...E LOS NUEVOS COMPO NENTES SI LOS COMPONENTES NO SON RECIBIDOS DENTRO DE ESTE PERIODO UNA FACTURA SER EMITI DA A SU CUENTA LOS PRECIOS DE PARTES DE RECAMBIO RECONSTRU IDAS ESTAN DISPONIBLES SOLO CON LA...

Страница 96: ...7 PVO2D 607 PVO2D 607 PVO2D 607 V lvula de Control Final PVO2D 607 PVO2D 607 PVO2D 607 PVO2D 607 Interruptor de Circuito 515KZ 615 515DZ 615 515DZ 615 515KZ 615 Ventilador de Enfriamiento 515UK 634 51...

Страница 97: ...566 Medidor de Tiempo PV5LD 617 PV5LD 617 PV5LD 617 PV5LD 617 Panel de Luces 303DS 615 303DS 615 505DZ 615 505DZ 615 Monturas de Motor 505IZ 609 505IZ 609 505IZ 609 505IZ 609 Tuerca Montaje de Compres...

Страница 98: ...os 2 5 LPM y menos 3 Peso 50 lbs 22 7 kg Nivel de Sonido ISO 8359 1996 desde el frente 48 0 dbA promedio general Dimensiones 27 75 Alto x 16 Ancho x 14 Prof 70 5 x 40 6 x 35 6 cm V lvula de Alivio de...

Страница 99: ......

Страница 100: ...Sunrise Medical Respiratory Products Division 100 DeVilbiss Drive Somerset PA 15501 800 333 4000 In Canada 800 263 3390 814 443 4881 Sunrise Medical 04 07 LT 1928 Rev A...

Отзывы: