MODEL 177

A special feature of this syringe is the small hole in the
head, by which the flow of solution can be regulated.
Maximum flow is obtained when this hole is covered with a
finger. Removing finger stops solution if air-line pressure is
twenty pounds or less, and reduces flow if air-line pressure
exceeds twenty pounds.

TO USE

—To secure best results, fill container no more than

two-thirds full. Can be operated with either compressed air
or hand bulb. If hand bulb is used, give taper connection a
slight twist to make it hold securely. Grasp the bulb firmly,
using the fingers against the palm of the hand, rather than
two or three fingers against the thumb.

This syringe is especially convenient for washing wax

out of the ear. Also for general use where controlled stream
is desired. Large size 6-ounce bottle holds an adequate
supply of liquid.

TO CLEAN

—Unscrew and remove syringe tube. Insert a fine

wire into the back end of the tube and run it through until
it reaches the forward opening. The illustrations below show
details of this cleaning operation. IMPORTANT—Only a very
fine wire should be used in cleaning the tube, as a strong one
might push through the forward end, breaking the tip.

TO STERILIZE

—Autoclave (remove the plastisol bulb and

black washer). Use 

1

3

bleach to 

2

3

water for not more than 10-

15 minutes. Vanisol, Alconox Cidex, and Blue Chip are some
of the many commercial sterilizing solutions on the market.
Be sure to follow the manufacturer's directions for mixing and
using these products. After cleaning, be sure to rinse atomiz-
er with warm or hot water and air dry before adding medica-
tion. The Sterrad 100S System is also compatible.

Disassemble the syringe by rotating
the cap in a counterclockwise direc-
tion. The spray tube assembly can be
removed from the cap by rotating it in
a counterclockwise direction.

13

Unscrew and remove syringe tip.

Insert cleaning wire into back
end of tube and run it through
to forward opening.

MODEL 175

This Powder Blower diffuses powder medication evenly and
perfectly. When making application to the ear, the single
tube does not obscure the light.

TO USE

—Be sure all parts are clean and dry before using. To

secure best results, fill bottle not more than two-thirds full.
May be operated with either compressed air or a hand bulb.
If a hand bulb is used, grasp the bulb firmly, using the fin-
gers against the palm of the hand, rather than two or three
fingers against the thumb.

TO CLEAN

—Run a pipe cleaner into the tube as illustrated

and well up into the head as far as it will go.

Disassemble the atomizer by rotating the cap in a counter-
clockwise direction. The spray tube can be removed from the
cap by rotating it in a counterclockwise direction.

TO STERILIZE

—Wipe carefully with gauze or absorbent

cotton moistened with alcohol or other germicidal solu-
tions suitable for sterilizing purposes.

12

P o w d e r   B l o w e r s

S y r i n g e

Содержание DeVilbiss 119

Страница 1: ...DeVilbiss Atomizers Nebulizers Syringes Powder Blowers Instruction Guide Atomizer Models 15 RD 151 163 286 RD Nebulizer Models 45 180 646 Powder Blower Models 119 175 Syringe Model 177 ...

Страница 2: ... 6688 DECLARATION OF CONFORMITY 3 ATOMIZER 15 RD Adjustable Tip Atomizer 4 151 Vacuum Type Atomizer 5 163 All Purpose Atomizer 6 286 RD Physician s Non Corrosive Atomizer 7 NEBULIZERS 45 Medical Nebulizer 8 646 Nebulizer 9 180 Nebulizer 10 POWDER BLOWERS 119 Powder Insufflator 11 175 Physician s Powder Blower 12 SYRINGE 177 Syringe 13 WARRANTY 14 FRONT COVER ENT HandiPak Kit Model 7200D Includes m...

Страница 3: ...s of spray application shown in the following illustrations If they are kept clean and used as instructed they will be com pletely satisfactory in both operation and service Illustrations are based on x ray research TO USE Fill bottle to shoulder Grasp bulb firmly using fingers against palm of hand When spraying throat REMOVE nasal guard Swing spray tip up or down to direct spray as desired When s...

Страница 4: ...t results fill the bottle not more than two thirds full Push the spray tube firmly into the head of the atomizer so both black o rings are seated in the atomizer head Atomizer may be operated with either compressed air or hand bulb If hand bulb is used grasp the bulb firmly using the fingers against the palm of the hand rather than two or three fingers against the thumb TO CLEAN Use a fine wire an...

Страница 5: ...rts and mouthpiece should be rinsed with hot tap water after every use by removing bulb I from neb ulizer base H and cleaned at least once a day Your physician or dealer may specify a certain cleaning procedure If so follow their recommendations 4 Using two clean plastic containers or bowls fill one with hot water and dishwashing detergent for washing the other with hot water and vinegar solution ...

Страница 6: ...end of the inhalation remove finger from thumb valve and hold breath for two seconds 7 Remove nebulizer from mouth and exhale slowly This procedure should be repeated until all prescribed medication is neb ulized Blow through T piece Model 646 nebulizer is designed to remain in the mouth during exhalation if desired 8 Nebulizer may be used without mouthpiece Position nebulizer aerosol port in mout...

Страница 7: ...tions with an oil or glycerin base For best results fill bottle not more than one quarter full This nebulizer can be operated with either compressed air or a hand bulb If hand bulb is used grasp the bulb firmly using the fingers against the palm of the hand rather than two or three fingers against the thumb For a dry vapor turn the little metal table inside the bot tle to a horizontal position For...

Страница 8: ... and Blue Chip are some of the many commercial sterilizing solutions on the market Be sure to follow the manufacturer s directions for mixing and using these products After cleaning be sure to rinse atomiz er with warm or hot water and air dry before adding medica tion The Sterrad 100S System is also compatible Disassemble the syringe by rotating the cap in a counterclockwise direc tion The spray ...

Страница 9: ...n sating for costs incurred in rental while said unit is under repair or costs for labor incurred in repairing or replacing defective part s THERE IS NO OTHER EXPRESS WARRANTY IMPLIED WAR RANTIES INCLUDING THOSE OF MERCHANTABILITY AND FIT NESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE EXPRESS LIMITED WARRANTY AND TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WAR RANTIES ARE ...