MODEL 119
TO USE
—Be sure all parts are dry before using. Fill bottle
no more than half way to shoulder of the bottle with dry
powder. For measured dosages, add desired amount of dry
powder to bottle. Do not over-tighten bottle. Grasp the bulb
firmly, using the fingers against palm of hand. If necessary,
tube can be unthreaded slightly to administer powder in
other directions.
TO CLEAN
—If powder is kept dry, there is little chance for
clogging. If damp powder remains in the tube and becomes
caked, unthread tube and remove residue with pipe cleaner.
For best results, remove powder, rinse and thoroughly dry
the bottle and tube before storing for extended period of
time. Do not store with powder in bottle.
TO STERILIZE
—Wipe carefully with gauze or absorbent cot-
ton moistened with alcohol or other germicidal solutions
suitable for sterilizing purposes.
CAUTION
—DO NOT USE HEAT; it may damage the unit.
11
Shoulder
MODEL 180
For Vaporizing Oil or Glycerin-Base Solutions
This nebulizer produces a vapor instead of a spray. It
may be used wherever a vapor is indicated, as in treatment
of the lower respiratory tract or very sensitive nasal tract.
Any deep-seated conditions can be treated with the nebu-
lizer, as the vapor reaches, by inhalation, even the most
remote regions to which it is directed.
TO USE
• Use only solutions with an oil or glycerin base. For best
results, fill bottle not more than one-quarter full.
• This nebulizer can be operated with either compressed
air or a hand bulb. If hand bulb is used, grasp the bulb
firmly using the fingers against the palm of the hand,
rather than two or three fingers against the thumb.
• For a dry vapor, turn the little metal table inside the bot-
tle to a horizontal position. For a moist vapor, turn it to
a perpendicular position.
• Nebulizer is equipped with both a
vented and a plain nasal guard. The
nasal guard with ventilating
grooves prevents any undesirable
excess of air pressure in the nasal
cavities. This extra low-pressure
feature ensures against any possi-
ble harm to delicate membranes.
The plain guard is for inflation pur-
poses. In attaching either nasal
guard to the nebulizer, give it a
slight twist to make it fit tightly.
TO CLEAN
— Unscrew and remove spray unit from bottle.
Unscrew and remove glass tube with its metal ferrule. Wipe
the nozzle point clean. If this does not remove obstruction,
run a fine wire through the glass tube and metal ferrule.
Replace glass tube and screw metal part to bottle.
TO STERILIZE
1. Remove plastic nasal guard.
2. Pass spray tube through flame; or boil metal parts and
plastic guard.
3. Disassemble the atomizer by rotating the cap in a coun-
terclockwise direction.
4. The spray tube assembly can be removed from the cap
by rotating it in a counterclockwise direction.