Use the holes(5.0mm) marked '
'. To create the conductive connection (frame is anodized), use
Stainless steel M5nut, two Stainless steel cut washer, Stainless steel M5 plain washer, Stainless steel M5
spring washer ,
M5
copper wire ,and Stainless steel M5 bolt.
1. Copper wires with M5 cupped washer should be placed through the bolt;
2. Put the cut washer through the bolt, and the bolt must be put through the hole fixed in the aluminum frame;
3. Use the nut and cut washer to fix all the parts. The copper wire can not be attached to the aluminum.
●
Do not interrupt or influence the conductive connection when making daily maintenance .All the crunodes on
the conductive connection must be fixed. The fastness does not depend on soldering.
7
、
Suggested maximum number of modules in parallel and in series
●
When designing the system,
we recommend that the maximum number of modules in parallel should be no more than four while the
maximum number of modules in series no more than eight.