Antisepsis: keep away from salt erode and sulfuration places   

5

Mounting and notes 

 

  The modules’ electrical performance in a system is the same. When connected in series, all modules must 

have the same amperage. When connected in parallel, the modules must all have the same voltage. Connect 

the quantity of modules that match the voltage specifications of the devices used in the system. The modules 

must not be connected together to create a voltage that is higher than the permitted system voltage.   

  To minimize risk in the event of an indirect lightning strike, avoid forming loops when designing the system.   

● 

Modules must not be fitted as overhead glazing. Ensure that the mounting system can also withstand the 

anticipated wind and snow loads.   

● 

Precipitate can run off through small openings on the back side of the module. Make sure that the openings are 

not masked after mounting.   

● 

The maximum load on the module must not exceed 2.4kN

/㎡.

To avoid exceeding the maximum load, 

site-specific live loads such as wind and snow should be taken into account.   

● 

The installation of project must be facing north in the southern hemisphere, and facing south in the northern 

hemisphere, the electricity will be comparatively lower when the project facing west or east. The incorrect 

installation will lead to the loss of power   

 

 

 

 

 

 

 

 

 

● 

The modules, which are connected in series, must be in the same angle, otherwise, it will lose power because 

of the difference in sunlight intensity. Solar modules generate the power to the maximum when they are 

pointed directly at the sun. For installations where the solar modules are mounted to a permanent structure, 

the solar modules should be tilted for optimum winter performance. As a rule, if the system power output is 

adequate in the winter, it will be satisfactory during the rest of the year. The module tilt angle is measured 

between the solar modules and the ground. 

 

RECOMMENDED TILT ANGLES FOR A FIXED SYSTEM   

SITE LATITUDE IN DEGREES   

FIXED TILT ANGLE   

0

 o

 TO 15

 o

 

  15

 o

 

15

o

 TO 25

o

 

  SAME AS LATITUDE   

25

o

 TO 30

o

 

  L5

 o

 

30

o

 TO35

o

 

  L10

 o

 

35

o

 TO 40

o

 

  L15

 o

 

40

o

    +   

L20

 o

 

Содержание SR220-250P SERIES

Страница 1: ...ules mainly include220W 225W 230W 235W 240W 245W 250W 1 Electrical Specification POLY Si series PHOTOVOLTAIC MODULE Model SR220 250P Number of cells pcs 60 Pmpp W 230 3 Voc V 38 0 3 Isc A 8 18 3 Vmpp...

Страница 2: ...ight 50mm 1 97inch 2 Weight 21 5Kg 3 Cell 60 pcs 156mm 156mm solar cells 6 lines10 rows connected in series and array in matrix 4 Output cable 4mm2 cable with TUV certification with polarity mark wate...

Страница 3: ...CLIMATE CONDITION Install the PV module in the following conditions Environment temperature 47 2 Operating temperature 40 to 85 Waterproof don t dip the modules into the water or continually explode...

Страница 4: ...aximum load site specific live loads such as wind and snow should be taken into account The installation of project must be facing north in the southern hemisphere and facing south in the northern hem...

Страница 5: ...diode to decrease the loss of energy the shadow will lead to the loss of output power 6 Grounding All module frames must be attached to an earth ground A qualified electrician must do the ground conn...

Страница 6: ...t through the hole fixed in the aluminum frame 3 Use the nut and cut washer to fix all the parts The copper wire can not be attached to the aluminum Do not interrupt or influence the conductive connec...

Страница 7: ...urface of the wall or roof is required to prevent wiring damage and to allow air to circulate behind the module The recommended stand off height is 115mm If other mounting means are employed this may...

Страница 8: ...ed through the shaded area by the other modules When a bypass diode is wired in parallel with the series string the forced current will flow through the diode and bypass the shaded module thereby mini...

Страница 9: ...ped or rubbed away when dry as this will cause micro scratch We recommend that the system be inspected at regular intervals 13 Checklists All fastenings are tight and secure and free of corrosion All...

Страница 10: ...k on the rear of the module using sharp objects Exercise utmost caution when working on wiring and the inverter Be sure carefully to follow manufacture s installation instructions Artificially concent...

Отзывы: