www.sunred.nl
A.
Construction
and
characteristics
Transportable
terrace/garden
heater
with tank housing
Casing in steel with powder-coating(PBF-B) or in stainless steel(PBF-A).
Gas hose connections
with metal clamp (screw caps for Germany)
Heat
emission from reflector
B.
Specifications
Use propane,butane or their mixtures gas only.
Max.
wattage: 3000 watts
Min.
wattage: 2000 watts
Consumption:
APPLIANCE CATEGORY:
I
3+(28-30/37)
I
3B/P(30)
I
3B / P ( 50 )
3B/P(37)
TYPES
OF
GAS:
Butane
Propane
Butane, propane
or their mixtures
Butane, propane
or their mixtures
Butane, propane
or their mixtures
GAS
PRESSURE:
OUTLET PRESSURE
OF REGULATOR:
28-30mbar
37 mba
30 mbar
50mbar
37mbar
30mbar
37 mbar
30 mbar
50mbar
37mbar
Using the proper regulator according to outlet pressure of regulator as showed in the table above.
C.
Table
of
injector
APPLIANCE CATEGORY:
I
3+(28-30/37)
I
3B/P(30)
I
3B/P(50)
I
3B/P(37)
TYPES
OF
GAS:
Butane
Propane
Butane, propane
or their mixtures
Butane, propane
or their mixtures
Butane, propane
or their mixtures
GAS
PRESSURE:
TOTAL
HEAT
INPUT (Hs):
(Qn)
INJECTOR
SIZE:
28-30mba
37 mbar
30 mbar
50mbar
37mbar
3kW (218g/h)
3.2kW (233g/h)
0.85 mm
for
main
burner
0.75 mm
for
main
burner 0.85 mm
for
main
burner
0.18
mm
for
pilot burner
0.18
mm
for
pilot
burner 0.18
mm
for
pilot burner
The marking
,
for example
,
0.85 on the injector
,
indicates that the size of injector is 0.85mm
The hose and regulator assembly must conform to local standard codes.
Regulator outlet pressure should meet the corresponding appliance category in B. Specification.
The appliance requires approved hose in 1.4m length.