All In One Heat Pump For Domestic Hot Water
- 15 -
Connection of Electric
Electrical wire assembly
NOTE
The equipment must be applied specific power supply, supply voltage must
comply with rated voltage;
Power supply circuit must be fitted with ground wire, and ground wire of power
supply must be reliably connected with external ground wire;
The operation must be worked by professional personnel based on circuit
diagram;
Set up leakage protection device well according to the National Technical
Standard for electrical equipment;
1. Power Specification
Remark: Ple
ase directly connect power supply wire with user’s plug when use the heat
pump.
Item
Model
Power
supply
The finest wire diameter
(mm2)
Manual switch
(A)
Leakage
protection
device
YT-300TB1
220V/60Hz
Size
(continuous
length ≤ 30m)
Ground
wire
Capacity Fuse
Below 30mA
0.1sec
≥2.5
≥Φ1.0mm
≥20
20