All In One Heat Pump For Domestic Hot Water
- 11 -
Remark: According to actual needs, solar coils can be connected to
solar heat panels
、
floor heating
、
deicing
、
hot-tube
、
and so on.
II. Water Pipe Installation Instructions
1. Please don’t use iron pipe connect to heat pump, please use CPVC pipe, PPR pipe
or PB pipe;
2. Please according to the drawing shows to install the water pipes, connectors etc,
if the ambient temperature is below 0
℃
, proper insulation must be taken for the
water pipes;
3. Water inlet/outlet size is G3/4’’, external thread;
4. The water pipe’s work life should not less than heat pump’s work life;
5. Relief valve is G1/2’’, 0.8 MPa, after installation, must sure that the drainage pipe
which connect with the relief valve, is not blocked;
NOTE
The relief valve need to be pulled one time every six months for purpose of
taking calcium carbonate out and ensuring no obstacle, outlet temperature of
drainage port may be high, please be careful;