Sunrain YC-007TB1 Скачать руководство пользователя страница 29

- 27 -

12. Technical parameter

Model No.

YC-007TB1

YC-010TB1

YC-012TB1

Power Supply

230V / 1/ 50 Hz

230V / 1/ 50 Hz

230V / 1/ 50 Hz

Heating Capacity(kW)

¹

7.2

10.0

12.5

Power Input(kW)

¹

1.19

1.63

2.05

COP

¹

6.05

6.13

6.10

Heating Capacity(kW) ²

5.1

7.2

9.5

Power Input(kW) ²

1.00

1.40

1.86

COP ²

5.10

5.14

5.11

Cooling Capacity

kW)

4.5

6.5

8.5

Power Input

kW)

1.30

1.80

2.39

EER

3.46

3.62

3.56

Max Power Input(kW)

1.8

2.5

3

Max Current(A)

9.1

12.6

15.2

Refrigerant Type

R410a

R410a

R410A

Heat Exchanger

Titanium

Titanium

Titanium

Casing Material

ABS plastic

ABS plastic

ABS plastic

Water Flow Volume(m

3

/h)

3

4

4.8

Net Dimensions(L*W*H)(mm)

972*430*653

972*430*653

972*430*653

Package Dimensions (L*W*H)(mm)

1022*460*788

1022*460*788

1022*460*788

Working temperature range(°C)

-7

43

-7

43

-7

43

Noise(dB)

≤ 48

≤ 48

≤ 49

Net Weight(kg)

46

51

58

Gross Weight(kg)

59

65

73

Water connection(mm)

50

50

50

Testing condition: ¹ Heating Capacity at Air temp. 27°C/24°C, Water in/out temp. 27 °C/29 °C

² Heating Capacity at Air temp. 15°C/12°C, Water in/out temp. 26 °C/28 °C

Cooling Capacity at Air temp. 35°C/24°C, Water in/out temp. 29 °C/27 °C

Содержание YC-007TB1

Страница 1: ...Installation Operation Manual Swimming Pool Heat Pump Thank you very much for purchasing our product please keep and read this manual carefully before you install heat pump...

Страница 2: ......

Страница 3: ...1 2 Wire controller 1 3 Wire controller box and sponge pad Will install on the heat pump shell 1 4 Wire controller Cable 1 5 Drain pipe 2 m 1 6 Drain pipe connector 1 7 Rubber shock absorber 4 8 Heat...

Страница 4: ...nding The unit is not suitable for using in the winter the water reserved in the pipe network system must be drained Content Accessories description 3 Attention for safety 4 Heat pump unit working pri...

Страница 5: ...do not suggest to install auxiliary electric heaters in the system If must install auxiliary electric heaters must install the electric heaters by the specialized persons and our company has no respon...

Страница 6: ...or air outlet Because the internal rotor high speed operation may cause injury When an exception happens burning smell turn off the manual power switch immediately stop operating and contact with afte...

Страница 7: ...with the water then the refrigerant is condensed and becomes the saturated or over cooling high pressure and high temperature refrigerant liquid The water is heated up by heat pump when absorbing the...

Страница 8: ...r name etc avoid incorrect installation Make sure enough space for installation and maintenance Make sure barrier free for air inlet and outlet also dry ventilated place Make sure the bearing surface...

Страница 9: ...llation base for the heat pump Please refer to Figure 4 A n ch o r b o lt Drainage tray Heat Pump Installation base Concrete Anchor bolt Screw nut washer Shock absorb Heat Pump Drainage tray Figure 4...

Страница 10: ...x the whole system before install the water pipes Water inlet and outlet pipes shall be protected by the insulation layer Stable water velocity shall be ensured so that excessive throttling can be avo...

Страница 11: ...YC 007TB1 DN50 DN50 YC 010TB1 DN50 DN50 YC 012TB1 DN50 DN50 The swimming pool heat pump adopt the titanium heat ex changer can connect the swimming pool directly but must install a water filtration eq...

Страница 12: ...5 bar The flow switch can be installed on the horizontal pipeline or the vertical pipeline which the fluid flow direction is upward but should not be installed on the vertical pipeline which the flui...

Страница 13: ...not interfere with each other but not with the connecting pipe and the valve body contact If the unit is not matching the power line please supply specifications refer to provisions wires connecting i...

Страница 14: ...12 NOTE Here only for signal control never drive it directly Figure 11 Figure 12...

Страница 15: ...m Figure 13 COMP COMPRESSOR GND GROUND AMBT AMBIENT TEMPERATURE SENSOR WFS WATER FLOW SWITCH LOW LOW PRESSURE SWITCH HIGH HIGH PRESSURE SWITCH COIL EVAPORATOR COIL TEMPERATURE SENSOR OWT INWT INLET OU...

Страница 16: ...ght need repair Constantly bright at AUTO mode Extinguished Currently in the manual set temperature state Constantly bright this unit is a water connection heat pump Extinguished this unit is a refrig...

Страница 17: ...re off 3 Constantly bright Extinguished Timing working period 3 always on when set at other conditions are off Constantly bright start timing water return function Flashing start manual water return f...

Страница 18: ...er function when parameter 64 1 4 Under the main interface click to switch between heating and cooling operation status when parameter 64 0 5 time 1 In the main interface press to enter the clock sett...

Страница 19: ...water temperature In manual mode press or key to enter the water temperature setting state Then starts to display the setting symbol and display the corresponding water temperature set according to th...

Страница 20: ...ng period OFF respectively In the power on state heating cooling is performed only during the set working period and the rest of the time is not heating cooling When the start time and end time of a c...

Страница 21: ...3 0 disconnect 1 close EEV value 04 Measured value Evaporator coil sensor 05 Measured value ambient temperature sensor 06 Measured value absorption temperature sensor 07 Measured value exhaust tempera...

Страница 22: ...splay state click the button to start the manual water circulation function At this time the Back Pump icon flashes The manual return water control is as follows A no pipe temperature sensor When the...

Страница 23: ...e timed return water close time is reached in this process the timed return function will be turned off the return water function is still valid for next time unless the timed return function is turne...

Страница 24: ...ifreeze When the circulating water pump continuously stops for more than 30 minutes it starts for 60 seconds then repeats the cycle When the ambient temperature is 2 C and the water tank temperature i...

Страница 25: ...tch disconnected water cycle heat pump 02E exhaust temperature too high 03E high pressure switch failure 04E low pressure switch failure 09E communication failure 11E evaporator coil temperature senso...

Страница 26: ...stem affect the environment around Check if there is refrigerant leakage If any fault occurs please check the instructions first to analyze and remove the fault 10 Operation and maintenance 10 1 Perso...

Страница 27: ...ne or other flammable harmful gas we can only adopt compressed air fluoride or refrigerant for such experiment 10 4 To remove the compressor please follow the following steps Turn off the power supply...

Страница 28: ...26 11 Fault analysis and elimination method...

Страница 29: ...Type R410a R410a R410A Heat Exchanger Titanium Titanium Titanium Casing Material ABS plastic ABS plastic ABS plastic Water Flow Volume m3 h 3 4 4 8 Net Dimensions L W H mm 972 430 653 972 430 653 972...

Страница 30: ...28 After sale service If your hot water heater can not operate normally please turn off the unit and cut off the power supply at once then contact with our service center or technical department...

Страница 31: ......

Страница 32: ......

Отзывы: