- 9 -
5.2 Instruction
5.2.1 Marginal data
5.2.2 Pipeline installation diagram
Controller
Heat
Pump
Water temp sensor wire
.
Swimming Pool
Pump signal wire
Pump
Drainage
Drainage
Feeding water
Figure 7 Diagram
(
Single unit for reference
)
●The one-way valve is suggested for each unit, to prevent the water back flow.
●The system can be combined with multiple units, but should be controlled by each unit independently.
●Regarding the installation of backup pump, maintenance valve and temperature measure point, please
consider it yourself.
●All pipes and valves of the unit need the heat preservation.
5.2.3 Selection of the water pipes
Model No.
Inlet
Outlet
YC-007TB1
DN50
DN50
YC-010TB1
DN50
DN50
YC-012TB1
DN50
DN50
The swimming pool heat pump adopt the titanium heat ex-changer, can connect the swimming pool directly,
but must install a water filtration equipment before water go into heat pump, the filter meshes is about 40
meshes.
Main pipe diameter selection of the parallel connected multiple units (example)
Inlet/outlet pipe
YC-007TB1
One unit
DN50
Inlet/outlet pipe
YC-010TB1
One unit
DN50
Inlet/outlet pipe
YC-012TB1
One unit
DN50
●The pipe press and flow rate should be calculated before the diameter selection, the range of pressure
drop is 0.3
〜
0.5 kgf/cm2(3
〜
5m
)
the range of head pipe flow rate is 1 .2
〜
2. 5 m/s.
●The hydraulic calculation should be made after the selection of pipe diameter, if the resistance is more
than pump head, then need to choose a more power pump, or choose a bigger pipe.
Содержание YC-007TB1
Страница 2: ......
Страница 14: ...12 NOTE Here only for signal control never drive it directly Figure 11 Figure 12...
Страница 28: ...26 11 Fault analysis and elimination method...
Страница 31: ......
Страница 32: ......