background image

 

9

 

 

Your Guarantee 

 

If this product is found to be faulty as a result of faulty materials or 

workmanship within one year from date of purchase, it will be repaired 

free of charge. 

 

This guarantee is subject to the following terms: 

• 

Sunpentown must be notified of the fault. 

• 

Proof of purchase must be presented to Sunpentown’s nominated 
representative. 

• 

The warranty will be void if the product if modified, misused or repaired by 
an unauthorized person. 

• 

The warranty after repair will not be extended beyond the original one-year 
period. 

• 

All replacement parts will be new or reconditioned. 

• 

Parts, which are replaced, become the property of Sunpentown. 

• 

The warranty applies for the use of the product in the USA only. 

 

What is NOT COVERED: 

• 

Warranty does not include freight charges. 

• 

Damage due to installation error, product abuse and/or misuse.  

• 

Incidental or consequential damage caused by possible defects with this 
product. 

• 

Labor cost incurred for the installation and/or removal of a possible defective 
unit. 

• 

Damage to product caused by improper power supply voltage, accident, fire, 
floods or acts of nature. 

• 

Failure of product resulting from unauthorized modifications to the product. 

• 

Improper installation or failure to perform the necessary maintenance. 

• 

Normal wear and tear on parts or replacement of parts designed to be 
replaced. 

• 

Damage to personal property from use of product. 

• 

Replacement or repair of household fuses, circuit breakers, wiring or 
plumbing.

 

 

This GUARANTEE is in addition to your Statutory Rights 

 

SUNPENTOWN INTERNATIONAL INC. 

14625 Clark Ave. City of Industry, CA 91745 

Tel: 800-330-0388 

[email protected] 

www.sunpentown.com 

 

Содержание SF-615H

Страница 1: ...EVAPORATIVE AIR COOLER WITH HUMIDIFIER Model SF 615H Instruction Manual Please read this manual thoroughly before using this product Keep in a safe place for future reference ...

Страница 2: ...1 CONTENTS A PRODUCT INTRODUCTION 2 B TECHNICAL PARAMETER 2 C CONSTRUCTION DIAGRAM 3 D CONTROL PANEL OPERATION 4 5 MODE SCHEMATICS 6 E MAINTENANCE AND STORAGE 7 F CAUTION 8 G WARRANTY 9 ...

Страница 3: ...TRODUCTION OF FEATURES High grade computer controlled system with LED panel Remote control Functions Cool fan ultrasonic humidifier and air filtration Dust filter captures dust and pollen Honeycomb pad enhances cooling performance and added air filtration Energy saving and effective only uses 65W of power 3 fan speeds High Medium Low Large water tank capacity and high air volume Up to 12 hours off...

Страница 4: ...M Control Handle Wheel Air outlet Water level indicator Power cord Dust filter Water tank Back Honeycomb pad behind filter Remote Control The functions on the remote are the same as the control panel Mist nozzle Drain outlet ...

Страница 5: ...airflow adjust the horizontal louvers manually MODE button Selects the operating mode corresponding indicator light will illuminate If no indicator fan is under normal mode at selected speed Natural Imtates natural air flow Unit operates according to preset computer program alternating between different fan speeds Please refer to next page for schematics Sleep Unit operates according to preset pro...

Страница 6: ...water is added before turning on Cooling function Unit cycles the water to blow cool humidified air Add ice ice pack not included for added cooling When water falls below the MIN mark Cool Humidifying function will automatically shut off and the Evaporative cooling indicator will flash Please turn off this function or add water Once water is added indicator will stop flashing and unit resumes Cool...

Страница 7: ...speed t 0 HI MID OFF LOW t 80sec 5S 5S 5S 5S 7 5S 2 5S 5S 5S 5S 7 5S 5S 5S 5S 2 5S 2 5S 2 5S 2 5S 2 5S Sleep Mode Schematics High speed t 0 HI MID OFF LOW t 80sec 5S 5S 5S 5S 5S 5S 2 5S 2 5S 7 5S 5S 5S 5S 5S 5S 5S 5S 2 5S Medium speed t 0 HI MID OFF LOW t 80sec 5S 5S 5S 5S 7 5S 2 5S 5S 5S 5S 5S 5S 5S 5S 2 5S 2 5S 2 5S 2 5S 2 5S 2 5S Low speed t 0 HI MID OFF LOW t 80sec 5S 5S 5S 5S 7 5S 2 5S 5S 5S ...

Страница 8: ...fix the position The water tank should be cleaned periodically 1 With unit powered off and unplugged 2 Remove screws of the filter net and take out the filter and honeycomb pad 3 Clean tank with brush or cloth 4 There is a smaller water tank seated inside this main tank for the humidifier Unplug the rubber plug to both tanks to drain out dirty water Note the water tank CANNOT be removed due to tub...

Страница 9: ...l LED Do not use any corrosive cleaner or solvent Empty the water tank before moving the air cooler Before storage please clean filter honeycomb pad and drain both the humidifier water tank and the main tank Allow to dry completely Unplug power source when not in use Do not use the cool function in a damp and closed space Do not place fingers or insert foreign objects into the louver during operat...

Страница 10: ...OT COVERED Warranty does not include freight charges Damage due to installation error product abuse and or misuse Incidental or consequential damage caused by possible defects with this product Labor cost incurred for the installation and or removal of a possible defective unit Damage to product caused by improper power supply voltage accident fire floods or acts of nature Failure of product resul...

Отзывы: