Sunnex PF Series MRI Service & Installation Manual 

18

Risks associated with disposal of parts: 

To minimize risks associated with 

disposing parts, care should be taken to avoid cuts when dismantling bulbs, 
glass lens and other glass parts.  
 
While disposing parts and/or product, information on local, state, federal, or 
country requirements need to be met. 

 

7. MARKINGS 

 
7.1 SYMBOLS 

 

On/Off 
Switch 

Symbols 

 

Caution Symbol 

Protective 

earth terminal 

symbol 

This product must be sorted as 
Waste from Electrical and 
Electronic Equipment (WEEE) 

 

 

 

 

 

 

ON OFF  Consult 

User 

Guide 

Protective 

Earth 

Terminal 

WEEE 

 

Fuse 

Symbol 

Alternating Current 

Symbol 

Direct Current 

Symbol 

Hot Surface Symbol 

 

 

 

 

Fuse A/C 

DC  Hot 

Surface 

 

7.2 WARNIING STATEMENTS AND LABELS 

 

On lamp head 

 

CAUTION!  

ATTENTION! 

 

HOT SURFACE 

SURFACE CHAUDE 

 

CAUTION! 

LAMP TO BE OPERATED OUTSIDE 

THE BORE OF MRI MAGNET 

ATTENTION!

 LA LAMPE DOIT FONCTIONNER 

UNIQUEMENT EN DEHORS DU CHAMPS 

MAGNÉTIQUE DE D’IRM 

 
 

Содержание PF MRI Series

Страница 1: ......

Страница 2: ...DUCTION 4 3 PF SERIES MRI SPECIFICATIONS 5 3 1 TECHNICAL DATA 5 3 2 EMC COMPATIBILITY 6 3 3 TRANSPORTATION AND STORAGE 6 4 ASSEMBLY INSTRUCTIONS 7 4 1 PF SERIES MRI MOBILE PF28016 M 7 5 OPERATING INST...

Страница 3: ...arefully check the contents of the shipment Report shortages and or errors to Sunnex or your dealer s customer service department within five 5 working days The recovery of costs related to shipping d...

Страница 4: ...educated on the equipment to ensure continued safety and needed maintenance Be sure you understand the intended use of this equipment and recommended operation before attempting to install and use the...

Страница 5: ...Rendering Index 97 Total Weight Mobile 40 lbs 18 kg This product is Class I and the mode of operation is suited for continuous use Radiated and conducted emissions testing has been completed on the P...

Страница 6: ...ical Equipment WARNING The equipment or system should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary the equipment or system should be observe...

Страница 7: ...y modification to the structure of the light may also void the listings of this product 4 1 PF SERIES MRI MOBILE PF28016 M CAUTION THE ELECTRICAL BOX CONTAINS FERROUS MATERIALS AND MUST BE HANDLED WIT...

Страница 8: ...the weight caster and vertical pole are attached properly Figure 1 Installing counter weight to the caster base 2 Place lamp arm assembly into top of pole and secure in position with the set screw pr...

Страница 9: ...t fixture The guidelines and requirements of your MRI facility must be considered as well Consult with your MRI facility manager or the RF panel support technician if uncertain 1 Mount transformer box...

Страница 10: ...wire temperature rating 105 degree C should be used A typical installation is shown in following diagram A 3 pin 9 pin 25 pin D Sub connector can be used 5 Plug male connector from lamp cord into the...

Страница 11: ...SS ON THE MALE CONNECTOR FIRST 2 PUSH ON THE TAB OF FEMALE CONNECTOR AND HOLD 3 PULL THE MALE CONNECTOR OUT 6 Confirm connection through the RF panel into the light fixture in the MRI room 7 Plug elec...

Страница 12: ...ctrical box on wall 3 Velcro is provided on the base plate of the electrical box and a rope and snap on hook is provided on the electrical box to assist in proper installation 4 Plug lamp lead connect...

Страница 13: ...ous materials and must NEVER be placed close to the magnet If the electrical box is moved closer to the magnet at 100 gauss line electromagnetic interference may be seen to avoid this NEVER move the e...

Страница 14: ...r base is weighted for stability but the arm should not be locked in a fully extended horizontal position as this may compromise the stability of the fixture 6 SERVICE AND MAINTENANCE While your PF SE...

Страница 15: ...s needed with a damp cloth and a mild detergent For disinfection use a soft cloth with a disinfectant solution such as isopropyl alcohol NOTE Do not introduce any fluids to the inside of the lamp head...

Страница 16: ...new bulb straight into socket Note Do not touch the halogen bulb with bare fingers as dirt and oil from hands could cause a fire hazard 5 Reposition lampshade and components on lamp back Position the...

Страница 17: ...pe 250V 1 25A Interpower Products 813MDA 1 25 3 Follow procedure in reverse to return lamp to operating condition Figure 4 Fuse Replacement 6 4 PREVENTIVE INSPECTION AND MAINTENANCE Lens in lamp head...

Страница 18: ...YMBOLS On Off Switch Symbols Caution Symbol Protective earth terminal symbol This product must be sorted as Waste from Electrical and Electronic Equipment WEEE ON OFF Consult User Guide Protective Ear...

Страница 19: ...R CORD FROM WALL RECEPTACLE BEFORE SERVICING FUSIBLES PLACEES SOUS COUVERTURES T 2A 250V 2 AMP X 1 LE CABLE D ALIMENTATION EST SPECIFIQUE A UNE UTILISATION EN MILIEU HOSPITALIER DEBRANCHER LE CABLE D...

Страница 20: ...given within the Warranty Period If a Product is found to be defective and the provisions of this Section have been complied with Sunnex will repair or replace the Product at its expense Other than as...

Страница 21: ...acement procedure in the manual Fuse is blown Inspect replace the fuse following the fuse replacement procedure No power to the electrical box Check for facility power to the electrical box Power Supp...

Страница 22: ...rmittently when light head or arms are moved problem within transformer arm assemblies or other part of lighting system If problem cannot be repaired call Sunnex Customer Service Various arms do not m...

Страница 23: ...t guidance RF Emissions CISPR 11 Group 1 The PF MRI Light PF 28016 M uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference...

Страница 24: ...ypical commercial or hospital environment Surge IEC 61000 4 5 1 kV Differential 2kv Common 1 kV Differential 2kV Common Mains power quality should be that of a typical commercial or hospital environme...

Страница 25: ...000 4 6 3 Vrms from 150 kHz to 80 MHz V1 3 Vrms Portable and mobile RF communications equipment should be separated from the PF MRI Light PF 28016 M by no less than the recommended separation distanc...

Страница 26: ...I Light PF 28016 M can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF Communications Equipment and the PF MRI Light PF 28016 M as recommende...

Страница 27: ...Sunnex PF Series MRI Service Installation Manual 27...

Страница 28: ...Sunnex PF Series MRI Service Installation Manual 28 REV 1 1 AUGUST 2007...

Отзывы: