- 13 -
GD-1000 Control Box Circuit Board
CE(European specification)
- 14 -
GD-1000 Control Box Fuse
Fuse
Troubleshooting:
All of the heater panels are not heating up or there is no power from the
contrl box or the light :
1.Check if power cords are correctly connected for upper and lower dome.
2.If the fuse for the power cords is intact.
3.If there is a malfunction of transformer.
4.If there is a malfunction of relay.
If the fuse is broken or any
defect occurs:
1.The light will not function;
2.Domes will not heat up
or work;
UL specification: 10 A 250V
CE specification: 6.3 A 250 V
J2 power cord
(blue and brown)
output for under
dome
Transformer
Red and white cords:
connect to the fuse
J1 power cord
(blue and brown)
output for upper
dome
Connect to
the Buzzer
Relay
Power cords
(blue, brown and green)
Input Voltage: 220V
Provide power for upper
and under dome
EMI filter