Step 4: Setting high value

Step 5: Setting low value

Step 6: 24 hour log

Sensor calibration and hour setting

Click knob and turn to set high ppm value of 
selected zone. This is the maximum CO2 level 
the generator will allow. In fact, the generator will 
usually stop before reaching this level in order to 
avoid overshoots.

Click knob and turn to set low ppm value of selected 
zone. This is the minimum CO2 level the generator 
will allow. In fact, the generator will usually turn on be-
fore reaching this level in order to avoid undershoots.

Click knob and turn to select log time 
among last 24 hours; controller displays 
the min., average and max. ppm read-
ings observed during the selected hour, 
for each zone separately. 

WARNING

Sensor calibration is not required for a new unit (factory calibrated).

Verify CO2 sensor precision by exposing your unit to outdoor air every 6 months (correct value stands 
between 350 and 450 ppm). To calibrate your sensor, refer to Appendix 2. Hour can be set at all times; 
also refer to Appendix 2.

Appendix 2

Calibration of CO2 sensor

Important Notice : This step is not required for a new unit (factory calibrated).Verify 
CO2 sensor precision by exposing your unit to outdoor air every 6 months (cor-
rect value stands between 300 and 500 ppm). If you need to calibrate the sensor, 
please follow these instructions. At any time before the last step, the calibration 
procedure can be cancelled, causing the controller to return to normal operation.

WARNING EACH ZONE SENSOR MUST BE CALIBRATED SEPARATELY

1.

  IS CALIBRATION NEEDED?

 First select zone #1 or #2, 

then expose the correspponding remote sensor to outdoor 
air for a minimum of 5 minutes, fresh air being used as a 
reference. If the value on screen is around 350 to 450 ppm, 
YOU DO NOT NEED TO RECALIBRATE THE SENSOR OF 
THIS ZONE.

2.    CALIBRATION IS NEEDED : Click knob repeatedly until 

“Calibration” indicator turns ON.

3.  Press knob and keep it pressed for about 5 seconds, until 

light indicator begins to fl ash and “CAL“ appears on screen.

4.  Let button go, “CO2 CAL“ appears on screen, click knob 

again, then 400 will appear on screen to remind you that 
you need to place the unit in fresh air before starting the 
calibration. If your controller is not in fresh air condition, just 
click knob to abort calibration.

5.  STARTING CALIBRATION : press knob and keep it pressed 

for at least 5 seconds, until “CAL” shows up on screen, 
then let button go.

6.  Automatic calibration will take a few seconds to complete: 

“CAL good“ will appear on screen for 5 seconds, and con-
troller will return to normal operation automatically.

Calibration

Calibration

Time setting

Follow these instructions

1.  View current time by turning knob fully clockwise

2.  Click knob until << CALIBRATION >> indicator turns on

3.  Press knob for 5 seconds until CAL appears on screen

4.  Let knob go, you now enter the time setting mode

5.   Click knob to display current time. You must turn knob 

to set minutes before going to step 6

6.  Click knob and turn to set hours. Click knob to toggle 

between hours and minutes

7.  Press knob for 5 seconds until GOOD 

appears on screen

8. Let knob go to return to normal operation

Содержание Titan Controls Atlas 4

Страница 1: ..._______________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ________________________________________________ 1 Square 1 Foot ...

Страница 2: ...tory reconditioning if the unit is under warranty Contact the number below for a RMA and shipping address Complete the form below and include it with your unit Also please write the RMA on the outside of the box Please package the unit in its original packaging If it is damaged in shipment we cannot be responsible Once we receive the unit back we will repair or replace the controller within 48 hou...

Страница 3: ...ration WARNING EACH ZONE SENSOR MUST BE CALIBRATED SEPARATELY 1 IS CALIBRATION NEEDED First select zone 1 or 2 then expose the correspponding remote sensor to outdoor air for a minimum of 5 minutes fresh air being used as a reference If the value on screen is around 350 to 450 ppm YOU DO NOT NEED TO RECALIBRATE THE SENSOR OF THIS ZONE 2 CALIBRATION IS NEEDED Click knob repeatedly until Calibration...

Страница 4: ... Plug the CO2 generator and fan into Output Box 1 and the flap switch into the Output Box 2 Make sure the airflow is directed toward Room 1 when the flap switch is de activated 1 Controller 2 Output box 3 Sensor Sensor 4 Power supply 5 Network cable 6 Telephone cable Set up Mode F17 using ventilation fans and an ON OFF Switcher OSW sold separately Plug the CO2 generator into the upper outlet of Outpu...

Отзывы: