background image

14

SAC600

Safety  & Special Guidelines

•  Do not use unit near gas appliances, fires, or near flammable or combustible liquids

•  Do not incline the unit while moving

•  Do not mishandle or shake the unit

•  Keep the unit one yard away from televisions or radios to avoid 
  electromagnetic interference

•  Do not place air exhaust duct too close to walls to avoid overheating of unit

•  Do not use unit in crowded areas

•  Avoid direct sunlight on unit to retain color

•  Do not use the unit in water or near water to avoid electric shock

•  If the power cord is damaged, it must be replaced by a certified technician

•  Do not spray insecticide or other chemicals to avoid damaging the plastic housing

•  To prolong the life of the unit, please make sure water tank is emptied completely  
  before it is stored

•  When using the auto-drain for a long period of time, please connect the drainage pipe

When there are problems with the unit, please stop using it and ask for advice from your 
local dealer or manufacturer.

After running the unit for an extended period of time, there will be dust in the air intake 
duct and it could effect the efficiency of the unit. We suggest cleaning the air intake duct 
and the air filter occasionally or asking for advice from your local dealer.

When the unit begins to work inefficiently, is broken, or other problems arise, please turn 
off and unplug the unit and request service from your local service provider.

Содержание SAC600

Страница 1: ...is device beyond that which is described in this manual and or any unapproved attempt to repair this device will void the product s warranty and is undertaken at your own risk Sunleaves is not responsible for damage caused by inappropriate operation of this device Sunleaves Air Conditioner Thank you for purchasing this quality Sunleaves Air Conditioner ...

Страница 2: ...on 1 2 Technical Specifications 2 3 Package Contents 3 4 Operation 4 5 Maintenance Trouble Shooting 12 6 Safety Special Guidelines 13 7 Warranty Information 15 8 Service 15 9 Temperature Conversion Table 16 Sunleaves Air Conditioner ...

Страница 3: ...enient efficient and mobile air conditioning It is easy to use does not need installation and is simple to maintain The options for remote control or manual control along with an easy to read LCD display makes it effortless to operate The compact design and multiple functions along with minimal noise and power con sumption make this unit very competitive with other portable air conditioning units ...

Страница 4: ...ata printed on the label 5 The compressor inside this unit is not sealed so a small amount of air from the room in which it sits may be exchanged through the interior air inlet found on the back of the unit Technical Specification Model SAC600 Cooling capacity Btu h 12000 Dehumidifying G day 10 5 Power Cooling 1100W Dehumidifying 950W Heating N A Circulation volume CFM 205 Power source single phas...

Страница 5: ... Contents 1 Control Panel 2 Air Outlet 3 Handle 4 Caster 5 Interior Air Outlet 6 Exhausted Air Outlet 7 Exterior Air Inlet 8 Electric Cable 9 Duct Connector 2 10 Flex Tube 2 11 Remote Control 12 Drain Tray 13 Drain Cap ...

Страница 6: ...will run at auto mode and the LCD window will display AUTO Press the Power button while the unit is running and the unit turns off and the timer setting is cancelled but the other settings mode set temperature fan speed and air flow mode are still set Press Power button to turn the unit on and the unit starts running with the previous settings but the previous timer setting has been canceled 3 MOD...

Страница 7: ...IMER setting button AUTO OFF TIME SETTING While the unit is on press the TIMER button to set the desired OFF time The time setting ranges from 0 5 hours to 12 hours in half hour increments The timer setting will display in the LCD window AUTO ON TIME SETTING While the unit is off press the TIMER button to set the desired ON time The time setting ranges from 0 5 hours to 12 hours in half hour incre...

Страница 8: ...while the unit is off Mode Button Press to change the unit run mode Temp Button Press to increase set room temperature 1O F 1O C Wind Button Press wind button to start or stop air flow in a vertical direction Signal Transmission Indicator Press once will display informa tion in LCD window and it will disappear in a few seconds Speed Button Press once to change fan speed to Low Mid and High speed P...

Страница 9: ...f according to the room temperature Please point the remote control toward the signal receiver on the unit panel After the unit shuts off wait at least 3 minutes before you continue operation Operation 1 Insert batteries and press POWER button to turn the system on Wind Button Choose on or off mode ...

Страница 10: ...set temperature the compressor will start running When the room temperature is lower than the set temperature the compressor shuts off and the fan returns to the original speed 1 Insert batteries and press POWER to turn the system on Mode Temp Speed 3 Press TEMP but ton to set the desired room temperature 4 Press SPEED but ton to choose desired fan speed 1 Insert batteries and press POWER to turn ...

Страница 11: ... time 1 Insert batteries and press POWER button to turn the system on 3 Press Speed button to choose desired fan speed 2 Use the Timer but ton to set auto OFF time at 0 5 hour incre ments from 0 5 hour to 12 hours 3 To cancel OFF time press the TIMER button to 12 hours and press once more to cancel 4 When the unit is OFF press Timer button to set auto ON time 5 User the Timer button to set auto ON...

Страница 12: ...dow 2 Intake outer air and exhaust heated air from the door Open the window to fit the plastic ducting outside window and secure them out of the window Open the door to fit the plastic ducting and secure them outside of the door Warning The air exhaust duct must be placed above the air intake duct Duct can be placed on the ground safely When finished using the unit remove the ducts and store them ...

Страница 13: ...ause back flow triggering the auto shut off mechanism 2 The air exhaust duct must be placed above the air intake duct 4 In order to make sure the air intake duct functions properly please do not put any objects around the duct Otherwise the air conditioner will fail to remove the hot air and cool the condensor This will also cause the compressor to auto shut off 5 Follow all specifications or the ...

Страница 14: ... be easily damaged If the air filter is blocked the unit will not function properly Please clean air filter at least once every few weeks to avoid clogs To open the air filter 1 Open the air filter cover and remove air filter cover 2 Remove air filter from filter cover To clean the air filter Wash the air filter by immersing it gently into warm water with a neutral detergent Fully rinse the filter...

Страница 15: ... water tank 4 Re fasten the drain cap Before contacting repair services please check the following Problem Cause Solution The unit does not work Power supply faulty 1 Not plugged in 2 Bad plug or socket 3 Fuse blown or faulty wiring 1 Plug in correctly 2 Change the plug or socket 3 Send unit to service center to replace fuse fuse 3 15A 250V The unit stops running automatically Timer is set or room...

Страница 16: ...insecticide or other chemicals to avoid damaging the plastic housing To prolong the life of the unit please make sure water tank is emptied completely before it is stored When using the auto drain for a long period of time please connect the drainage pipe When there are problems with the unit please stop using it and ask for advice from your local dealer or manufacturer After running the unit for ...

Страница 17: ... your Portable Air Conditioner Note This form is available at www sunleaves com on the product information page for each covered product 7854 North State Road 37 Bloomington IN 47404 Phone 888 464 9676 Email info sunleaves com Sunleaves Garden Products Limited 1 Year Warranty Terms Subject to the following limitations Sunleaves Garden Products warrants that the Portable Air Conditioner will for 1 ...

Страница 18: ...ank you for purchasing this quality Sunleaves Air Conditioner Celsius Fahrenheit 15o 59 0o 16o 60 8o 17o 62 6o 18o 64 4o 19o 66 2o 20o 68 0o 21o 69 8o 22o 71 6o 23o 73 4o 24o 75 2o 25o 77 0o 26o 78 8o 27o 80 6o 28o 82 4o 29o 84 2o 30o 86 0o 31o 87 8o ...