6 Electrical Connection
33
Second PE Terminals
There is a second PE terminal on one side of the inverter. Users may choose to
connect PE connection.
Fig. 6-3
Second PE Terminals
Second PE Connection
Fig. 6-4
Connection of the Second PE Connection
*The connection parts are not included in the delivery scope.
6.5 Communication Connection
6.5.1 Communication Overview
The inverter operation information can be transferred via its integrated RS485
interface to a PC with monitoring software (such as SolarInfo Insight), or to data
logging device (such as SolarInfo Logger).
RS485 is the standard communication choice for inverter.
The communication terminals (RS485) are located at the bottom of the inverter.
And there are two optional connection terminals on the configuration circuit
board: RS485 A/B terminal blocks and RJ45 plug in terminals.
If a 120Ω terminating resistor is to be connected between the communication
cable A and B, connect the terminal resistance by using the dip switch.
Fig. 6-5
Communication Configuration
Before communication connection, prepare communication cable and RJ45
plug.
Item
Description
Remark
A
Screw
M4
×
12mm
B
Lock washer
-
C
Washer
-
D
Cable socket
-
E
Yellow-green
cable
6mm
2
(9AWG)