SG1K5TL-31
User Manual
66
8.8.7
Communication Parameters Settings
1. Long press button “
” to enter into
sub-screen.
2. Short press button “
” to select
icon “Set-param” and long press button
“
” to confirm the selection.
3. Short press “
” to move cursor
and short press “
” to set the password
1111.
4. Short press button “
” to select
icon “Com-param” and long press button
“
” to confirm the selection.
5. Short press button “
” to move
cursor and short press “
” to set
appropriate communication parameters.
Each inverter should have different address and have same baud rate to ensure
good communication.
Address range: 1~247
Baud rate: 1200,2400,4800,9600
Default protocol: Modbus