SG1K5TL-31
User Manual
62
8.8.3
Deviation of Energy Settings
If the accumulative value of “E-tot” by inverter has deviation from the value in the
external metering device, you should adjust the parameter “power-adj”.
1. Long press button “
” to enter
into sub-screen.
2. Short press button “
” to select
icon “Set-param” and long press button
“
” to confirm the selection
3. Short press “
” to move cursor
and short press “
ESC/
” to set the
password 1111.
4. Short press button “
” to select
icon “Sys-param” and long press button
“
” to confirm the selection.
5. Short press button “
” to select
icon “Power-adj” and long press button
“
” to confirm the selection.
6. Short press button “
” move
cursor and short press button “
ESC/
” to
set the correct time.
(Power-adj value)= (Real measured
value)-(E-tot reading value).
“+” can be changed to negative symbol “-”.
The adjustable range is from -9999~+9999
kWh. “E-tot” after “Power-adj” adjustment
must not be negative. Otherwise
“Power-adj” settings is not valid.