Product Certifications
CONFORMS TO:
(*)
EN 61000-6-2:2005
EN 61000-6-3:2007 + A1:2011
AS/NZS 60000-6-3:2012
FCC CFR 47 Part 15 Subpart B
(*)
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference, and 2) This device must accept any interference
received, including interference that may cause undesired operations.
(*) See Electromagnetic Compatibility below.
Setup
A four position DIP switch configures the output current display. To show output current from a single
controller IPN network address of the display and charge controller must match.
Dip
Switch
IPN Address - Output Current of Single Charger
Total Output Current
of All Chargers on IPN
Network
0
1
2
3
4
5
6
7
# 1 (A2)
OFF
(0)
OFF
(0)
OFF
(0)
OFF
(0)
ON
(1)
ON
(1)
ON
(1)
ON
(1)
X
# 2 (A1)
OFF
(0)
OFF
(0)
ON
(1)
ON
(1)
OFF
(0)
OFF
(0)
ON
(1)
ON
(1)
X
# 3 (A0)
OFF
(0)
ON
(1)
OFF
(0)
ON
(1)
OFF
(0)
ON
(1)
OFF
(0)
ON
(1)
X
# 4 (IPN
Total)
OFF
(0)
OFF
(0)
OFF
(0)
OFF
(0)
OFF
(0)
OFF
(0)
OFF
(0)
OFF
(0)
ON (1)
Installation
This unit is designed to be used with Integrated Power Net™ (IPN™) compatible charge controllers. Do not
plug into anything other than an IPN compatible communications port. Each charge controller includes
an IPN DISPLAY connector which provides power and IPN network connection. The IPN-Remote can
plug into any charge controller on the network using the standard 4 conductor RJ-11 voice telephone
cable supplied. Standard 4-pin telephone cables swap pin numbers end-to-end. If cables are custom
terminated or cable couplers are used, be certain pin swap is maintained. Do not expose to rain, snow or
excessive moisture. Total maximum cable length should be limited to approximately 500 feet (152.4 m).
Electromagnetic Compatibility
(CE and FCC Marks)
To comply with electromagnetic compatibility requirements the IPN Remote must be installed with a
clamp on type ferrite suppressor (included with the products). The clamp suppressor must be installed
around the remote display cable with the cables looped to pass through the core 2 times. Additional
suppressors can be ordered as BSE p/n 523-0005-01.