BUCK-BOOST TRANSFORMER
BUCK-BOOST TRANSFORMERS SHOULD NEVER BE USED TO BOOST POWER BEING
SUPPLIED TO ENTIRE TANNING SYSTEM. POWER TO THE FACIAL TANNER CIRCUIT SHOULD
ONLY BE BOOSTED WHEN REQUIRED (SEE EXPLANATION BELOW).
The use of Buck-Boost transformers is NOT REQUIRED on units that do NOT have a facial tanner. A
Buck-Boost transformer is not required for tanning systems with a facial tanner being installed in
locations where the incoming power is 240V. A tanning system equipped with a facial tanner will
require the use of a Buck-Boost transformer in locations where the incoming voltage to the salon is 208
volts.
A 0.15KVA transformer (JK Products PN #) boosting voltage from 208V to 230V supporting AMP load
capacity of 7.0 AMPS is required to be used with the model having a facial tanner on 208V systems.
The Buck-Boost transformer should be installed on the right leg behind the tanning system (enough
cable should used when wiring the Buck Boost transformer to allow the tanning system to be moved a
minimum of 24 inches away from the wall for service requirements).
All wiring and connections
should conform to local and national electrical codes.
The facial terminal block and facial relay are located on the power box.
CAUTION: To avoid personal
injury and electrical shock hazard all electrical connections must be completed with the power
to the tanning system off.