CAPRI Models
Voltage
230 VAC
230 VAC
Frequency
50Hz
50Hz
Max. Current Draw
12.1 Amps
*
23.6 Amps
**
Wattage:
2.8kW
5.4kW
Number of Wires
Three
Three
*
Standard 12.1 Amp (2.8kW) configuration: the heater
will not operate
while the jets pumps is running.
**
Alternate 23.6 Amp (5.4kW) configuration: the heater
will operate
while the jets pumps is running.
Listed above are the most common power configurations by model.
Current/wattage requirements for each model change depending on
device* availability. Basically, the more functions (electrical devices) in a
spa, the greater its current/wattage demand. Refer to the jumper
configuration/max current chart (page 38) for a complete listing of power
requirements for each device within your spa.
*Device = Heater, Pump(s), Blower
7.0 Start-Up Instructions
FOR BEST RESULTS, READ EACH STEP IN ITS ENTIRETY BEFORE
PROCEEDING WITH THAT STEP.
A. Prepare Hot Tub for Filling
• Clear all debris from the hot tub. (Although the hot tub shell has been
polished at the factory, you may want to treat it with a specially
formulated hot tub cleaner and wax available from your dealer prior to
filling the first time.)
• Remove the filter lid (Figure-F, Page 14), then remove filter cartridge as
illustrated in section 11.1, page 26-27.
B. Fill Hot Tub
• Place the end of your garden hose into the empty filter bucket.
NOTE:
Never fill with water from a water softener. If your water is extreme-
ly “hard”, it is preferable to fill half-way with hard water and the rest of the
way with softened water. Or, you may fill entirely with hard water if you use
a special water additive available from your Sundance dealer.