9.0 

Operating Instructions

The spa control system has automatic functions that 
operate upon startup and normal operation to protect 

the system.  Upon power up, the readout displays the 
following information:

1.    Control panel displays current software release  

(e.g. 3.56), then;

2.  Control panel displays “888” and all indicator LEDs are 

lit, permitting visual inspection of all display segments 
and indicator lights for proper operation. 

3.  After the initial start-up sequence ends, the actual water temperature 

is displayed.  If water temperature at this time is less then the factory 
default temperature setting of 100 °F (38 °C) and the spa is set to 

filtration/heating mode “F0”, “F1”, “F2” or “F3” (

page 28), the heater 

will turn on and run until the water temperature rises to the factory 

setting, then turn off.  Note: it is common for the heater to turn on 
after the spa is first filled because tap water is often very cold. 

4.  Approximately two minutes after power is applied to the spa, the first 

filtration/heating cycle turns on pump 1.  In Certa/Chelsee/Hamilton

 

models, an automatic five minute “blow-out” function also activates 
pump 2 for a period of five minutes to flush all lines.  Then, after five 

minutes, pump 2 turns off and pump 1 continues to operate for the 
duration of the cycle.  

Note: this function only occurs during the first 

filtration/heating cycle each day.

9.1  Setting Water Temperature 

The spa’s thermostat provides optimum control of water 
temperature.  The temperature setpoint (set temperature) 
can be adjusted from 65-104 °F (18-40 °C).  To raise the set 
temperature, press the 

WARMER (   ) 

button. To lower the 

set temperature, press the 

COOLER (   ) 

button.  

Note: The first press 

of either WARMER (   ) for COOLER (   ) button displays the set 
temperature.

9.2  Activate Jets Pumps

The 

JETS 1

 button activates the functions of the main 

2-speed jets pump.  The first press activates pump 1 in 

low speed, the second press activates high speed, and the 
third press shuts the pump off. For 2-pump models, the 

JETS 2

 button controls jets pump 2 which only operates in 

high speed.  Both pumps have a twenty minute default when manually 
activated.

1.

2.

3.

1.

2.

3.

1

2

1

2

Содержание 780 Metro

Страница 1: ...CamdenTM CertaTM ChelseeTM HamiltonTM MetroTM 6530 436 Rev B...

Страница 2: ...ne 3 0 4 0 ppm Free Bromine 2 0 4 0 ppm Total Alkalinity 100 120 ppm Calcium Hardness 150 250 ppm Always maintain your spa filter as outlined below to ensure healthy spa water Refer to page 29 30 for...

Страница 3: ...Functions 20 8 1 Control Panel All Models Except Metro 20 8 2 Control Panel Metro Models Only 21 8 3 General Spa Features And Controls 22 9 0 Operating Instructions 23 9 1 Setting Water Temperature 2...

Страница 4: ...nance System 37 13 0 Error Conditions Error Messages 37 13 1 Summer Logic 37 13 2 Overheat Condition 38 13 3 Panel displays SN1 38 13 4 Panel displays SN2 38 13 5 Panel displays FL1 or FL2 38 13 6 Pan...

Страница 5: ...21 0 Optional SunSound Stereo Receiver Functions 48 21 1 SunSound Audio Receiver Specifications 54 21 2 Audio System Remote Control 56 21 3 Optional MP3 Player Connection 57...

Страница 6: ......

Страница 7: ...rein 2 0 FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable...

Страница 8: ...ould the need arise to replace the suction fittings or the pump be sure that the flow rates are compatible Never operate the spa if the suction fittings are broken or missing Never replace a suction f...

Страница 9: ...y vary as much as 5 F 2 C 12 The use of alcohol drugs or medication before or during spa use may lead to unconsciousness with the possibility of drowning 13 Persons suffering from obesity or a medical...

Страница 10: ...reduce the risk of electric shock connect the local common bonding grid in the area of the spa to these terminals with an insulated or bare copper conductor not smaller than No 6 AWG 10mm2 4 All field...

Страница 11: ...of alcohol or drugs can greatly increase the risk of fatal hyperthermia in spas 3 2 Hyperthermia Prolonged immersion in hot water may induce hyperthermia A descrip tion of the causes symptoms and effe...

Страница 12: ...a or when you are wet unless such appliances are built in by the manufacturer 7 Proper chemical maintenance of spa water is necessary to maintain safe water and prevent possible damage to spa componen...

Страница 13: ...of uniformly supporting this weight without shifting or settling for the entire time the spa is in place If the spa is placed on a surface which does not meet these requirements damage to the skirt a...

Страница 14: ...he spa the entire time it is in place Proper support is critical especially if the spa is to rest on a second story or higher For spas that are to rest on balco nies roofs or other platforms not speci...

Страница 15: ...or city building ordinances WARNING In addition to maintenance of filters and water chemistry proper ventilation is recommended to reduce the risk of exposure to viruses and bacteria that could be pre...

Страница 16: ...A and 30A configuration the heater will not operate at the same time as the high speed jets pump The factory setting is 120V 15A Note all Canadian spas must be hard wired 120 VAC or 240 VAC per CSA Ca...

Страница 17: ...pump 2 runs only in high speed In 50A configuration the heater will not operate while both jets pumps are running in high speed Note pump 2 runs only in high speed This is the factory setting in 60A c...

Страница 18: ...Chelsee Hamilton Models These spas must be permanently connected hard wired to the power supply No plug in connections or extension cords are to be used in conjunction with the operation of these spa...

Страница 19: ...or on terminal blocks TB1 and TB3 Figures C F page 14 TIGHTEN SECURELY All wires must be hooked up securely or damage could result 10 Install control box door and screws and reinstall the cabinet side...

Страница 20: ...Canada Metro Convertible Models 120 VAC 3 Wire Connection 60Hz BLUE BLUE BROWN BROWN 1 2 US Canada Camden Certa Chelsee Hamilton Models 240 VAC 3 Wire Connection 60Hz Figure F TB1 All Export Models 23...

Страница 21: ...to the empty filter bucket CAUTION Never fill with water from a water softener If your water is extremely hard it is preferable to fill half way with hard water and the rest of the way with soft ened...

Страница 22: ...zer reading within the levels recommended by the Association of Pool And Spa Professionals USA printed on the inside cover of this manual If sanitizer levels cannot be stabilized perform the decontami...

Страница 23: ...low the set temperature 8 Place Cover On Spa Keeping the insulating cover in place anytime the spa is not in use will reduce the time required for heating thereby minimizing operat ing costs The time...

Страница 24: ...If spa is indoors open doors and windows for proper ventila tion Turn on all spa jets pumps for one hour open all air controls and place all massage selector knob s in their center combo position as...

Страница 25: ...ION Never leave your spa unattended for any reason while the cover is open and accessible to small children and animals CAUTION To prevent the unlikely possibility of contracting a waterborne illness...

Страница 26: ...pump 2 off G Light On Off Button Turns waterfall footwell and control lights on in unison Press once for high intensity press a second time for medium intensity press a third time for low intensity p...

Страница 27: ...press a second time for high speed press a third time to turn pump 1 off F Light Button turns underwater light on in random color mode or in one of six solid colors Refer to section 9 5 page 24 for d...

Страница 28: ...Chelsee Hamilton Models only Light feature not offered on Metro Models Waterfall function not offered on the Metro Models 1 2 278 12 2 4c 12 4d 4a 4b 12 5 3c 3b 3a 1 12 10 9 8 6 7 13 11 13 Hamilton m...

Страница 29: ...o the spa the first filtration heating cycle turns on pump 1 In Certa Chelsee Hamilton models an automatic five minute blow out function also activates pump 2 for a period of five minutes to flush all...

Страница 30: ...r counterclockwise to close Note To minimize heat loss close all air controls when spa is not in use Certain jets may not draw air while the jets pump is running in low speed this is considered normal...

Страница 31: ...gh Speed Color Blend Mode Displays hunderds of colors in 5 second intervals Low Speed Color Blend Mode Displays hundreds of colors in 20 seconds intervals OR Special Effects Mode Overrides All Modes D...

Страница 32: ...ll Operation All Models Except Metro Turn waterfall control valve counterclockwise to increase waterfall s output Turn control valve clockwise to decrease or turn off waterfall s output Note it takes...

Страница 33: ...0 2 below for additional information 10 1 Standard Filtration Heating Modes F0 F3 Standard filtration heating modes are typically selected by customers in cold climates where heat up times are extende...

Страница 34: ...filtration heating per day one 30 minute cycle every eight hours F6 2 hours of filtration heating per day one 30 minute cycle every six hours Lock Modes L1 Lock Out disables all spa functions to permi...

Страница 35: ...ilters must remain in place to protect these components from debris entrapment damage They should be cleaned every 2 months or when weak pump 2 performance is observed ALWAYS TURN POWER TO SPA OFF BEF...

Страница 36: ...ilter after 3 months use or as needed DO NOT REUSE Reuseable filter Loosen filter nut to provide clearance then remove filter assembly Note The Stage 2 filter cartridge cannot be cleaned and must be t...

Страница 37: ...posite end of garden hose away from spa fig H 4 Pull outward on garden hose end at drain connection approx 3 8 to open drain valve and release water from spa fig I Water drains at approximately 3 gall...

Страница 38: ...inward with thumbs to curl pillow lip inward so you can grab it with fingertips 3 4 5 Flex pillow lip inward 2 3 to get a good grip on the ends Gently pull outward on pillow to release mounting stud...

Страница 39: ...ditional force at position A to continue rotation until you feel a click at position B then feel the internal release at position C It may seem like your are over torqu ing the jet internal between po...

Страница 40: ...s little or no maintenance of any kind To clean simply wipe cabinet with a clean towel and mild soap solution CAUTION Never spray cabinet with a garden hose for any reason since this action may induce...

Страница 41: ...rtment Replace the drain plugs 6 Loosen the hose clamp on the circulation pump intake behind the control box Figure A page 13 and pull the hose off twist hose back and forth while pulling outward Tip...

Страница 42: ...The midpoint of 7 is said to be neutral above which is alkaline and below which is acidic In spa water IT IS VERY IMPORTANT TO MAINTAIN a slightly alkaline condition of 7 4 to 7 6 Problems become prop...

Страница 43: ...cals is not covered under the spa s warranty 13 0 Error Conditions Error Messages 13 1 Summer Logic When the actual spa water temperature reaches up to 2 F 1 C above the set temperature the spa goes i...

Страница 44: ...d their meanings 13 3 Panel displays SN1 Open sensor heater is disabled or shorted sensor spa is deactivated The high limit temperature sensor is not function ing Your authorized dealer must repair th...

Страница 45: ...6 Panel displays COL Cool Condition Temperature has dropped 20 F 11 C below the current set temperature The pump and heater have been activated to bring the temperature to within 15 F 8 C of the set...

Страница 46: ...ake sure power is going to the spa and check the water level If it does not solve the problem con tact your authorized Sundance dealer 2 The main pump operates but no water flows to jets Pump may not...

Страница 47: ...ealer so that they may arrange service We build the best spas in the industry Nonetheless we are always striving to improve the quality and features of our products Your input as a Sundance spa owner...

Страница 48: ...cluding interference that may cause undesired operation J20 J21 J12 J14 J16 J11 J15 J13 J17 J7 J8 J9 J10 J5 J6 Heater IN Heater OUT F1 K1 K2 K3 K4 K5 K7 K8 J1 Control Panel Ozonator O 3 GRN TB1 Standa...

Страница 49: ...ay not cause harmful interference 2 This device must accept any inteference received including interference that may cause undesired operation Heater 5 5 kW 240 VAC STEREO Optional Power Supply OZONAT...

Страница 50: ...mful interference 2 This device must accept any inteference received including interference that may cause undesired operation Heater 5 5 kW 240 VAC 40A Logic 40A PUMP 2 HI RED BLK STEREO Optional Pow...

Страница 51: ...4 J16 J11 J15 J13 J17 J7 J8 J9 J10 J5 J6 Heater IN Heater OUT F1 K1 K2 K3 K4 K5 K7 K8 BLK WHT BRN BRN BLU BLU BLU BRN BRN BLK BLU BRN BLU BRN J1 Control Panel Ozonator O 3 TB1 230 VAC 3 Wire Connectio...

Страница 52: ...5 8 7 7 6 2 4 HI LO C Control Panel CIRC PUMP SPA LIGHT J20 K1 K2 K3 K4 K5 K6 K7 K8 J21 J11 J12 J13 J14 J15 J16 J17 J18 J19 J7 J8 J9 J10 Heater 2 7 kW 230 VAC OZONATOR OPTIONAL O 3 GRN TB1 230 VAC 3...

Страница 53: ...JP1 4 2 3 1 6 5 8 7 7 6 2 4 HI HI LO C Control Panel CIRC PUMP SPA LIGHT J20 K1 K2 K3 K4 K5 K6 K7 K8 J21 J11 J12 J13 J14 J15 J16 J17 J18 J19 J7 J8 J9 J10 Heater 2 7 kW 230 VAC STEREO Optional Power Su...

Страница 54: ...settings to customize the sound in your spas audio system It s easy simply press the EQ LD but ton 2 to activate the DSP Then repeatly press the button again and you will be able to choose from Jazz P...

Страница 55: ...st selection press Volume Up or Volume Down Bass control Adjusts the amount of low frequency Treble control Adjusts the amount of high frequency Balance control adjusts the amount of sound output to t...

Страница 56: ...play song tracks Press again to turn off this feature 14 Preset 5 DN Button In tuner mode any station can be stored as preset 5 by simply pressing and holding this button for several seconds To recall...

Страница 57: ...OPEN and flip down the front access panel then press the Eject button located to the left of CD slot 20 USA Europe Switch Not Illustrated You can switch between American USA and European radio freque...

Страница 58: ...laytime 3 Folder name 4 File name 5 Song name 6 Artist s name 7 Album name The system can only display the first 8 letters of ID3 tags If the recorded information is longer than 8 letters text will sc...

Страница 59: ...e Display key 25 Reading MP3 files from a disc When a disc containing MP3 data is loaded the unit checks all the data on the disc If the disc contains numerous folders with many levels it takes a long...

Страница 60: ...ntrusion CFR 46 Rated Conformal Coated Printed Circuit Boards ASTMB117 Salt Fog Tested 400 Hours ASTM D4329 UV Stable Tested 400 Hours Double Sealed Water Protection Transport Gaskets White Low Curren...

Страница 61: ...rward Example of a disc s folder file hierarchy Folder File Level 1 Level 2 Level 3 Level 4 Level 5 Operation of the keys Press and hold to return 10 files behind Press Track Down to select folder dow...

Страница 62: ...peration details A LED Display displays the current radio or CD operation functions and presets B Feature not available C Station Preset Button Press to choose next AM FM radio preset station D Tuning...

Страница 63: ...um play list and start playback prior to plugging in MP3 Player 2 Press Source Button on stereo receiver or remote until the display reads AUX as shown C Operating MP3 Player All playback operations a...

Страница 64: ...nstalled in accordance with Article 810 of the National Electric Code ANSI NFPA 70 F Do not service this product yourself as opening or removing covers may expose you to dangerous voltage or other ris...

Страница 65: ...Notes...

Страница 66: ...Notes...

Отзывы: