Page 11
Export 1-Pump Camden/Metro Models (50Hz)
230V/20A*
230V/30A**
Voltage:
230 VAC
230 VAC
# of Wires:
3
3
Frequency:
50Hz
50Hz
Current Draw:
15A
21A
Circuit Breaker:
20A
30A
*
In the 20A configuration, the heater
will not operate
at the same time as
the high speed jets pump.
This is the factory setting.
**
In the 30A configuration, the heater
will operate
at the same time as the
high speed jets pump.
5.2 Export 50Hz Power Options
t
US/Canada Certa/Chelsee/Hamilton
2-Pump Models (60Hz)
240V/40A*
240V/50A**
240V/60A***
Voltage:
240 VAC
240 VAC
240 VAC
# of Wires:
3
3
3
Frequency:
60Hz
60Hz
60Hz
Current Draw:
26A
36A
45A
Circuit Breaker:
40A, 2-Pole
50A, 2-Pole
60A, 2-Pole
*
In 40A configuration, the heater
will not operate
while either jets pump
is running in high speed.
Note: pump 2 runs only in high speed.
**
In 50A configuration, the heater
will not operate
while both jets pumps
are running in high speed.
Note: pump 2 runs only in high speed.
This
is the factory setting.
***
in 60A configuration, the heater
will operate
while both jets pumps are
running in high speed.
Note: pump 2 runs only in high speed.
Export 2-Pump Certa/Chelsee/Hamilton Models (50Hz)
230V/20A*
230V/30A**
230V/40A***
Voltage:
230 VAC
230 VAC
230 VAC
# of Wires:
3
3
3
Frequency:
50Hz
50Hz
50Hz
Current Draw:
15A
23A
29A
Circuit Breaker:
20A
30A
40A
*
In 20A configuration, the heater
will not operate
while either jets pump is
running in high speed.
This is the factory setting.
Note: pump 2 runs
only in high speed.
** In 30A configuration, the heater
will not operate
while both jets pumps
are running in high speed.
Note: pump 2 runs only in high speed.
*** In 40A configuration, the heater
will operate
while both jets pump are run-
ning in high speed.
Note: pump 2 runs only in high speed.