background image

 8

5. Installation of Mounting Brackets and
First Sealing Strip
        

NOTE: 

Windows come in a variety of different 

styles. Therefore, it may be necessary to modify
or improve  your particular installation.

A. Attach the 

bracket assembly

 to 

90 angle support 

brackets

 (

Fig. 5

) using (2) 

1 1/2"  bolts

 

Two bolts per bracket. Secure with the (2) 

1/4" lock washers

 and (2) 

1/4"nuts. DO NOT 

immediately tighten these bolts as it may be 
necessary to adjust the depth of the 

bracket 

assembly,

 depending on the depth of your window sill. 

See

 (Fig. 7).

Install the two 

leveling screws

 into the

90  support brackets.

 

Test the bracket assembly in the 

window before cabinet installation. If the leveling 
screws are distanced too far away from the wall to
provide stability, it may be necessary for you to fill
this area with a solid piece of wood. See

 (Fig. 8).

  

Fig. 5

Bracket Assembly

Bracket Bolts

Leveling Screw

V-slot

90  Angle
Support Brackets

(TOP VIEW)

Center

Window sill

V-slot

(2) 3/4" screws per bracket

Bracket Assembly

Leveling Screw

Outer Wall Construction

3/16" Maximum

B. Measure the inside window sill width and find the 
center as shown in 

 (Fig. 6)

. Align the 

V-slot

 in each 

bracket on these marks and mount the brackets to the 
sill using  

3/4" screws

 provided. Brackets should be 

perpendicular to the inside window sill. 

See (Fig. 6).

C. For proper condensation run-off it will be necessary 
to adjust the angle/pitch of the window brackets. This is 
accomplished by adjusting the distance of the leveling 
screw on the outer wall. The maximum angle/pitch 
should not exceed more than 3/16". See (

Fig.7)

.

Use a solid piece of wood to provide stability. This 
will be required when sills are extra deep.
See (

Fig. 8).

CAUTION

!

!

Window Sash

Window Sash
Sealing Strip

Solid Piece Wood
(If required)

Fig. 6

Fig. 7

Fig. 8

Fig. 9

Installation instructions

Measurement for Model 10K =9.6" 
Measurement for Model 12K = 10.3" 
Measurement for Model 15K to 24K = 12.6" 

D. Cut 

the seal strip

 to fit the underside of the bottom 

window sash

. Remove the peel-off backing on the 

seal and attach it to this sash. 

See (Fig. 9).

Measurement for Model 8K = 7.5" 

 7.5" 

 12.6" 

 12.6" 

 7.5" 

Содержание SAW24CR3FHUE

Страница 1: ...User s Manual 24 000 BTU Room Air Conditioner SAW24CR3FHUE PTT042106...

Страница 2: ...Contents Parts Identification Introduction Electrical Specifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide Page 2 2 4 5 6...

Страница 3: ...before starting This manual contains information for the installation and operation of your room air conditioner Note The figures in this manual are based on the external view of a standard model Cons...

Страница 4: ...the air conditioner you have selected Introduction Control Panel Part Identification Remote control model Cabinet Exterior Air Inlet Air Outlet Fresh Air Vent Lever Control Panel Power Cord Front Pane...

Страница 5: ...to use the correct power supply according to the rating plate of your air conditioner 125 8K 15K 22K 24K Table 1 15 15 If the air conditioner has a serial plate rating of 115 volts and up to and incl...

Страница 6: ...ling setting To avoid installation operating difficulties read the instructions thoroughly NOTE Save the shipping carton and packing materials for future storage or transport of the unit Please check...

Страница 7: ...designed to fit easily into a single or double hung window However since window designs vary it may be necessary to make some modifications for safe and proper installation B Make sure window and fra...

Страница 8: ...er 1 4 screw For 8K to 12K models Channel 1 4 Screw Fig 3 Fig 4 Installation instructions 3 Assembly of the upper lower channels to the cabinet A L Shaped Top Channel Stick the double adhering seal to...

Страница 9: ...3 4 screws per bracket Bracket Assembly Leveling Screw Outer Wall Construction 3 16 Maximum B Measure the inside window sill width and find the center as shown in Fig 6 Align the V slot in each brack...

Страница 10: ...Shutters A Carefully slide the air conditioner back into the cabinet Please seek assistance for this procedure B Reinstall the slide out chassis security screws removed earlier on both sides of the ca...

Страница 11: ...moval may be excessive enough to overflow the unit or increase the noise of the air conditioner If this occurs you may wish to attach a drain hose not included to the drain plug allowing condensations...

Страница 12: ...air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW COOL NOTE After setting t...

Страница 13: ...e below 32 the Temperature display L0 Room Temperature above 99 the Temperature display H1 NOTE Temperature setting range is from 19 66 to 31 88 Fan Speed button Used to select fan speed in sequence a...

Страница 14: ...ct the Auto mode fan speed 9 Saver BUTTON Used to select the mode Energy saving The Above symbols are shown when the relevant mode is in use High fan speed Medium fan speed Low fan speed Auto fan spee...

Страница 15: ...ignal receptor of indoor unit The remote control is NOT preset as Cooling only or Heat Pump by manufacturer Each time after the remote control replaces batteries or is energized the Cooling indicator...

Страница 16: ...front grille To remove the air filter open the air inlet grille and take the air filter To reinstall the air filter reverse the above procedure DO NOT forget to install the air filter If the air cond...

Страница 17: ...ngle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot and humid weather Add flexible tubi...

Страница 18: ...reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty i...

Отзывы: